Weber 55052 0100 Safe handling tips for Liquid Propane Gas Cylinders, Liquid Propane LP Cylinders

Page 32

Safe handling tips for Liquid Propane Gas Cylinders

Liquid Propane (LP) gas is a petroleum product as are gasoline and natural gas. LP gas is a gas at regular temperatures and pressures. Under moderate pressure, inside a cylinder, LP gas is a liquid. As the pressure is released, the liquid readily vaporizes and becomes gas.

LP gas has an odor similar to natural gas. You should be aware of this odor.

LP gas is heavier than air. Leaking LP gas may collect in low areas and prevent dispersion.

To fill, take the LP cylinder to an RV center, or look up “gas-propane” in the phone book for other sources of LP gas.

WARNING: We recommend that your LP cylinder be filled at an authorized LP gas dealer, by a qualified attendant, who fills the tank by weight.

IMPROPER FILLING IS DANGEROUS. WARNING: If you exchange your LP cylinder,

make sure you get a similar tank in return. Your LP cylinder is equipped with a quick closing coupling or type 1 valve and an OPD (Overfilling Prevention Device). Other LP cylinders may not be compatible with your barbecue connection.

Air must be removed from a new LP cylinder before the initial filling. Your LP dealer is equipped to do this.

The LP cylinder must be installed, transported and stored in an upright position. LP cylinders should not be dropped or handled roughly.

Never store or transport the LP cylinder where temperatures can reach 125° F (too hot to hold by hand - for example: do not leave the LP cylinder in a car on a hot day).

Note - A refill will last about 20 hours of cooking time at normal use. The fuel scale will indicate the propane supply so you can refill before running out. You do not have to run out before you refill.

Treat “empty” LP cylinders with the same care as when full. Even when the LP tank is empty of liquid there still may be gas pressure in the cylinder. Always close the cylinder valve before disconnecting.

CAUTION: When transporting the LP cylinder make sure the plastic dust cover is in place over the valve. This will keep dust and dirt from the threaded portion of the valve.

Do not use a damaged LP cylinder. Dented or rusty LP cylinders or LP cylinders with a damaged valve may be hazardous and should be replaced with a new one immediately.

Liquid Propane (LP) Cylinder(s)

The joint where the hose connects to the LP cylinder must be leak tested each time the LP cylinder is reconnected. For example, test each time the LP cylinder is refilled.

Be sure the regulator is mounted with the small vent hole pointed downward so that it will not collect water. This vent should be free of dirt, grease, bugs etc.

The LP cylinder and connections supplied with your Weber Gas Barbecue have been designed and tested to meet government, American Gas Association, and Underwriters Laboratories requirements.

(1)

DOT 4BA240

00/00

(2)

Liquid Propane Cylinder requirements

Replacement LP cylinders supplied by Weber satisfy the above requirements. Check to be sure other cylinders have a D.O.T. certification(1), and date tested(2) is within five years. Your LP gas supplier can do this for you.

If you have questions about spare LP cylinders contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

All LP tank supply systems must include a collar to protect the cylinder valve.

The LP cylinder must be a 20-lb. size (18 1/4 inches high, 12 1/4 inches in diameter).

The LP cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (D.O.T.).

D-7

Image 32
Contents Gas Grill Liquid Propane GAS Units only Palatine, IL Customer Service CenterSouth Hicks Road Contents Operating For Installation in CanadaStorage Genesis Silver-C LP Page Page Page Page Assemble wheel frame Assemble frameContinue frame assembly Complete frame assemblyYou will need caster frame and wheel frame Add front panelAdd cooking box assembly Insert castersAdd fuel gauge Install cylinder panelFrame brace2 You will need burner control knobs Install igniterCheck that all burner valves are off You will need manifold bracket Install manifold bracketInstall the slide out bottom tray Install Lid You will need lid, two hair pin cotters1 and two hinge pins2Install the right end trim piece with tool holders Right swing-up work surfaceDo not use the swing-up work surface as a cutting BoardInstall side burner You will need side burnerWay and do not add bolts yet Install the left end trim piece and swing-up workShown, do not push the trim piece in all Do not use the work surface as a cutting board Install the work surfaceYou will need work surface Connection. Using a wrench could damage Fill liquid propane cylinderRegulator coupling and could cause a gas leak Closed. Close by turning clockwiseDo not use an open flame to check for gas Leaks. Be sure there are no sparks or openFlames in the area while you check for Leaks. Sparks or open flames will resultYou will need Bottom shelf Install the thermometerYou will need Thermometer Summary lighting instructions are on the control panel LightingTo Extinguish Manual Lighting Lighting the Side Burner Lighting only the side burnerStorage and/or Nonuse CleaningCooking Important LP Cylinder Information Refilling the Liquid Propane CylinderRemoval of the LP cylinder To Connect the hose to the cylinder Liquid Propane CylinderLiquid Propane Cylinder requirements Safe handling tips for Liquid Propane Gas CylindersLiquid Propane LP Cylinders Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsWeber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure Replacing Main Burners Crossover Ignition System Operations Barbecue temperature only Flame is low when burner is onBurners burn with a yellow or Orange flame, in conjunction withSide Burner does not light Flame is low in High positionFlame is very yellow Conjunction with the smell of gas