Step 11

Install igniter

Note - The igniter wires are already attached to the Gas Catcher Ignition Chamber and the igniter. This was done to factory test the ignition system.

The igniter lock nut is on the igniter.

Insert the top of the igniter up through the large part of the keyhole in the frame brace. Figure 19 (b). Loosen the igniter lock nut and slide the igniter into the small part of the keyhole. Figure 19 (c). Tighten the igniter lock nut. Figure 19.

Note - If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers.

(a)

Frame brace

(b)

Figure 19

 

 

 

Keyhole in

 

(c)

frame brace

Igniter lock nut

 

 

 

Frame brace

Small part of keyhole in frame brace

Step 12

Purge air from gas lines

You will need: one burner control knob.

mDANGER

Be sure there are no sparks or open flames in the area while purging. This can cause fire, explosion or serious bodily injury.

It is necessary to bleed the air out of newly installed gas lines. Turn gas supply ON at the source. Put on the front burner control knob. Push the front burner control knob down and turn to HI. When you start to smell gas, turn front burner control knob to OFF. Figure 20.

Figure 20

19

Image 19
Contents Genesis LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Operating area Gas supply testingGeneral Instructions StorageGeneral Specifications for Piping Typical natural gas supply installation to a wood deck Recommended concrete pad requirements Check package contents AssemblyStep Page Check contents of hardware packs Assemble the frame Continue frame assemblyMCAUTION a minimum of 2 bolts are required on each side Measure and drill holesMethod 2 Concrete Method 1 ConcreteMethod 3 Concrete Method 4 Wood deck Add cooking box Connect barbecue gas supply line to the natural gas supply Install manifold bracketCheck all valves are off Purge air from gas lines Install igniterMWARNING Do not ignite burners while leak checking Check for gas leaksAdd base panel Install side panelsInstall the bottom tray Install Flavorizer Bars and Cooking GratesAdd tool holders, control panel and burner control knobs Install LidInstall the accessory rack Install the condiment basketComplete accessory installation To Extinguish LightingManual Lighting Drippings and grease Periodic CleaningCooking After a Period of NonuseInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMain Burner Flame Pattern General MaintenanceMCAUTION Do not enlarge the burner ports when cleaning Weber Spider Stopper GuardsReconnect gas supply line. See Check for gas leaks Crossover Ignition System Operations MCAUTION Do not line the bottom tray with aluminum foil Burner does not light, or flame is low in High position43-47 Parts List Final Word Thanks