| SSE 5 BL |
5.1. Maintenance intervals | |
Daily: | Check warning signs on equipment for good legibility and completeness |
| Clean the filter: Use compressed air to blow through the filter (according |
| to the accumulation of dust) |
Monthly: | Check function of the device plug |
Every 6 months: | Check all electrical and mechanical connections for tight fit |
| Replace the filter (according to the accumulation of dust) |
Annually: | Replace outlet valve sealing. |
| Adjust valve switch |
FThe given maintenance intervals are average values.
Check whether in your individual case the maintenance intervals must be shortened.
5.2. Servicing the conveyor
Disconnect the unit from mains supply by the device plug.
Depressurize all system sections of the equipment
Disassembly the unit.
Maintenance 10