Teledyne Location and Mounting, Electrical Connections, Installation Model 3300PA

Page 18

3 Installation

Model 3300PA

 

 

 

 

 

 

 

 

 

3.2Location and Mounting

3.2.1 Control Unit Installation

The 3300PA Control Unit is designed to be rack mounted in a general purpose, indoor area, away from moisture and the elements. The unit should be installed at viewing level in a sheltered area.

Refer to the Outline diagram D-69220 for the physical dimensions of the analyzer.

3.2.2 Installing the Micro-Fuel Cell

A Micro-Fuel Cell is included as a separate item. It must be installed prior to instrument use.

Also, once it is expended, or if the instrument has been idle for a lengthy period, the Micro-Fuel Cell will need to be replaced.

To install or replace the Micro-Fuel Cell, follow the procedures in Chapter 5, Maintenance.

3.3Electrical Connections

Figure 3-1 shows the Model 3300PB rear panel. For detailed pinouts, see the wiring/interconnection drawings in the Drawings section at the rear of this manual.

Figure 3-1 Electrical Connectors for AC Control Unit

3-2

Teledyne Analytical Instruments

Image 18
Contents Model 3300PA Copyright 1999 Teledyne Analytical Instruments Contents Maintenance AppendixCombustible GAS Usage Warning This page left intentionally blank Main Features of the Analyzer Introduction OverviewPercent Oxygen Analyzer Introduction Front Panel Description Introduction Model 3300PARear Panel Description Rear PanelAnalog Outputs Percent Oxygen Analyzer Operational Theory Operational Theory IntroductionMicro-Fuel Cell Sensor Principles of OperationOperational Theory Model 3300PA Anatomy of a Micro-Fuel CellElectrochemical Reactions Effect of PressureCalibration Characteristics Characteristic Input/Output Curve for a Micro-Fuel CellSignal Processing ElectronicsGeneral Operational Theory Model 3300PA Installation Percent Oxygen Analyzer InstallationUnpacking the Analyzer Installing the Micro-Fuel Cell Installation Model 3300PAControl Unit Installation Location and MountingPercent Oxygen Analyzer Installation Gas Connections Sensor FailVacuum Service Option Installation Checklist Installation Model 3300 PAOperation Introduction Percent Oxygen Analyzer OperationUsing the Function and Data Entry Buttons Setting the Analysis RangesOperation Model 3300PA Percent Oxygen Analyzer Operation HI Range Setting the Alarm SetpointsSet Alarm LO RangeSensor Fail Alarm Selecting a Fixed Range or Autoranging CalibrationSupplementary Information Remove Power to Unit before replacing the fuse MaintenancePercent Oxygen Analyzer Maintenance Replacing the FuseWhen to Replace a Sensor Sensor Installation or ReplacementMaintenance Model 3300PA Ordering and Handling of Spare SensorsInstalling a Micro-Fuel Cell Removing the Micro-Fuel CellCell Warranty Conditions Appendix Specifications Percent Oxygen Analyzer AppendixSpare Parts List Appendix Model 3300PAReference Drawing MiscellaneousAppendix Model 3300PA