Teledyne operating instructions Front Panel Description, Introduction Model 3300PA

Page 8

1 Introduction

Model 3300PA

 

 

 

 

 

 

 

 

 

Operator can select Autoranging, which allows the analyzer to automatically select the proper preset range for a given measurement, or he can lock the analyzer onto a single range.

Twoconcentrationalarmswithadjustablesetpoints.

Sensorfailurealarm.

Three analog outputs: two for measurement (0–10 V dc, and negative ground 4–20 mA dc) and one for range identification (0-10 V dc).

Compact and rugged Control Unit with flush-panel case. Designed for indoor use.

1.3Front Panel Description

All controls and displays except the power switch are accessible from the front panel. See Figure 1-1. The front panel has seven pushbutton membrane switches, a digital meter, and an alarm indicator LED for operating the analyzer. These features are described briefly here and in greater detail in Chapter 4, Operation.

Figure 1-1: Front Panel

Function Keys: Seven pushbutton membrane switches are used to select the function performed by the analyzer:

Set Alarm 1

Sets Alarm 1 Hi or Low, and the concentration

 

 

at which alarm 1 activates.

 

 

1-2

Teledyne Analytical Instruments

Image 8
Contents Model 3300PA Copyright 1999 Teledyne Analytical Instruments Contents Maintenance AppendixCombustible GAS Usage Warning This page left intentionally blank Percent Oxygen Analyzer Introduction Main Features of the AnalyzerIntroduction Overview Front Panel Description Introduction Model 3300PARear Panel Description Rear PanelAnalog Outputs Operational Theory Introduction Micro-Fuel Cell SensorPercent Oxygen Analyzer Operational Theory Principles of OperationOperational Theory Model 3300PA Anatomy of a Micro-Fuel CellElectrochemical Reactions Effect of PressureCalibration Characteristics Characteristic Input/Output Curve for a Micro-Fuel CellGeneral Signal ProcessingElectronics Operational Theory Model 3300PA Unpacking the Analyzer InstallationPercent Oxygen Analyzer Installation Installation Model 3300PA Control Unit InstallationInstalling the Micro-Fuel Cell Location and MountingPercent Oxygen Analyzer Installation Gas Connections Sensor FailVacuum Service Option Installation Checklist Installation Model 3300 PAOperation Introduction Percent Oxygen Analyzer OperationOperation Model 3300PA Using the Function and Data Entry ButtonsSetting the Analysis Ranges Setting the Alarm Setpoints Set AlarmPercent Oxygen Analyzer Operation HI Range LO RangeSensor Fail Alarm Selecting a Fixed Range or Autoranging CalibrationSupplementary Information Maintenance Percent Oxygen Analyzer MaintenanceRemove Power to Unit before replacing the fuse Replacing the FuseSensor Installation or Replacement Maintenance Model 3300PAWhen to Replace a Sensor Ordering and Handling of Spare SensorsInstalling a Micro-Fuel Cell Removing the Micro-Fuel CellCell Warranty Conditions Appendix Specifications Percent Oxygen Analyzer AppendixSpare Parts List Appendix Model 3300PAReference Drawing MiscellaneousAppendix Model 3300PA