Teledyne 3300PA operating instructions Introduction Overview, Main Features of the Analyzer

Page 7

Percent Oxygen Analyzer

Introduction 1

 

 

 

 

 

 

Introduction

1.1Overview

TheTeledyneElectronicTechnologiesAnalyticalInstruments(TETAI) Model 3300PA is a microprocessor-based percent oxygen analyzer for real- time measurement of the percent of oxygen in inert gases, or in a wide variety of gas mixtures. It features simple operation, fast response, and a compact, rugged construction. Typical applications of the Model 3300PA are monitoring nitrogen generators and inert gas blanketing applications.

1.2Main Features of the Analyzer

The main features of the analyzer include:

High resolution, accurate readings of oxygen content from 0-1 % through 0-25 %, with 0-100% range optional. Large, bright, light- emitting-diode meter readout.

Simple pushbutton controls.

Nylon cell holder.

Advanced Micro-Fuel Cell, for percent analysis, has a two year warranty and an expected lifetime of 3 years.

Unaffected by oxidizable gases.

Fast response and recovery time.

Microprocessor based electronics: 8-bit CMOS microprocessor with on-board RAM and 16 KB ROM.

Two user selectable ranges (from 0-1 % through 0-25 %) allow best match to users process and equipment.

Air-calibration range for convenient spanning at 20.9 %.

Teledyne Analytical Instruments

1-1

Image 7
Contents Model 3300PA Copyright 1999 Teledyne Analytical Instruments Contents Appendix MaintenanceCombustible GAS Usage Warning This page left intentionally blank Introduction Overview Main Features of the AnalyzerPercent Oxygen Analyzer Introduction Introduction Model 3300PA Front Panel DescriptionRear Panel Rear Panel DescriptionAnalog Outputs Principles of Operation Operational Theory IntroductionMicro-Fuel Cell Sensor Percent Oxygen Analyzer Operational TheoryAnatomy of a Micro-Fuel Cell Operational Theory Model 3300PAEffect of Pressure Electrochemical ReactionsCharacteristic Input/Output Curve for a Micro-Fuel Cell Calibration CharacteristicsElectronics Signal ProcessingGeneral Operational Theory Model 3300PA Percent Oxygen Analyzer Installation InstallationUnpacking the Analyzer Location and Mounting Installation Model 3300PAControl Unit Installation Installing the Micro-Fuel CellPercent Oxygen Analyzer Installation Sensor Fail Gas ConnectionsVacuum Service Option Installation Model 3300 PA Installation ChecklistPercent Oxygen Analyzer Operation Operation IntroductionSetting the Analysis Ranges Using the Function and Data Entry ButtonsOperation Model 3300PA LO Range Setting the Alarm SetpointsSet Alarm Percent Oxygen Analyzer Operation HI RangeSensor Fail Alarm Calibration Selecting a Fixed Range or AutorangingSupplementary Information Replacing the Fuse MaintenancePercent Oxygen Analyzer Maintenance Remove Power to Unit before replacing the fuseOrdering and Handling of Spare Sensors Sensor Installation or ReplacementMaintenance Model 3300PA When to Replace a SensorRemoving the Micro-Fuel Cell Installing a Micro-Fuel CellCell Warranty Conditions Percent Oxygen Analyzer Appendix Appendix SpecificationsAppendix Model 3300PA Spare Parts ListMiscellaneous Reference DrawingAppendix Model 3300PA