Teledyne operating instructions Spare Parts List, Appendix Model 3300PA

Page 34

Appendix

Model 3300PA

 

 

 

 

 

 

 

 

 

A.2

Spare Parts List

QTY. P/N

DESCRIPTION

1

C-65220E

PC Board, Main

1

C-65220F

PC Board, Main for 0-100% range.

1

C-64586C

PC Board, Power Supply, AC Version

1

C-44611-I-22

Micro-Fuel Cell, I-22

2

F-1128

Fuse (AC), ½ A, 250 VAC, IEC Type T

1

F-274

Flowmeter 0.3-3.0 SCFH

IMPORTANT: Orders for replacement parts should include the part number and the model and serial number of the system for which the parts are intended.

Send orders to:

TELEDYNE ELECTRONIC TECHNOLOGIES

Analytical Instruments

16830 Chestnut Street

City of Industry, CA 91749-1580

Telephone: (626) 934-1500

TWX: (910) 584-1887 TDYANYL COID

Fax: (626) 961-2538

Web: www.teledyne-ai.com

or your local representative.

A-2

Teledyne Analytical Instruments

Image 34
Contents Model 3300PA Copyright 1999 Teledyne Analytical Instruments Contents Maintenance AppendixCombustible GAS Usage Warning This page left intentionally blank Introduction Overview Main Features of the AnalyzerPercent Oxygen Analyzer Introduction Front Panel Description Introduction Model 3300PARear Panel Description Rear PanelAnalog Outputs Percent Oxygen Analyzer Operational Theory Operational Theory IntroductionMicro-Fuel Cell Sensor Principles of OperationOperational Theory Model 3300PA Anatomy of a Micro-Fuel CellElectrochemical Reactions Effect of PressureCalibration Characteristics Characteristic Input/Output Curve for a Micro-Fuel CellElectronics Signal ProcessingGeneral Operational Theory Model 3300PA Percent Oxygen Analyzer Installation InstallationUnpacking the Analyzer Installing the Micro-Fuel Cell Installation Model 3300PAControl Unit Installation Location and MountingPercent Oxygen Analyzer Installation Gas Connections Sensor FailVacuum Service Option Installation Checklist Installation Model 3300 PAOperation Introduction Percent Oxygen Analyzer OperationSetting the Analysis Ranges Using the Function and Data Entry ButtonsOperation Model 3300PA Percent Oxygen Analyzer Operation HI Range Setting the Alarm SetpointsSet Alarm LO RangeSensor Fail Alarm Selecting a Fixed Range or Autoranging CalibrationSupplementary Information Remove Power to Unit before replacing the fuse MaintenancePercent Oxygen Analyzer Maintenance Replacing the FuseWhen to Replace a Sensor Sensor Installation or ReplacementMaintenance Model 3300PA Ordering and Handling of Spare SensorsInstalling a Micro-Fuel Cell Removing the Micro-Fuel CellCell Warranty Conditions Appendix Specifications Percent Oxygen Analyzer AppendixSpare Parts List Appendix Model 3300PAReference Drawing MiscellaneousAppendix Model 3300PA