Omron HBP-1300 Features / Functions of Unit, Front and back of unit, Meaning of the Symbols

Page 14

Features / Functions of Unit

Front and back of unit

4

6

 

 

5

2

3

 

 

7

 

1

1

2

3

 

Power ON / Measure blood pressure

 

Press when the power is off to turn on the power and start

[START/STOP] button

blood pressure measurement. During inflation or

(Power ON/OFF)

measurement, press to stop.

 

Power OFF

 

Hold down at least 3 seconds to turn off the power.

 

Press to enter “Menu Mode” and configure various settings.

[MODE] button

If held down at least 3 seconds when a measurement result

is displayed, the measured data is cleared without being

 

 

stored in memory.

 

Displays the system settings (page 16) and the last reading

[ ] [ ] button

(page 23). When using “Auscultation Mode”, inflates and

 

deflates the cuff.

4

Alarm lamp

Lights up or flashes when an alarm occurs (page 28).

5

NIBP connector

Connects the cuff tube.

 

 

 

6

DC jack

Connects the AC adapter.

 

 

 

7

Battery cover

Open to install or replace the battery.

 

 

 

Meaning of the Symbols

Symbol Description

Symbol Description

This shows the Type BF applied part.

Consult the instruction manual.

Class II (AC Adapter)

12

Image 14
Contents HBP-1300 Contents Exemptions IntroductionIntended Use General Information Setup Usage warnings and cautionsBefore use / during use Page Cleaning Maintenance and inspectionRechargeable battery Non-Invasive Blood Pressure Nibp measurement For cleaning, see Options Using the UnitComponents of the Product Key features, benefits, look Features of the ProductOptional Medical Accessories Front and back of unit Features / Functions of UnitMeaning of the Symbols LCD Display DIALow battery Installing the Battery PackBattery life Auto Power OffBattery level Connecting the AC AdapterBattery charging AC powerPress the Mode button System SettingsMenu Mode Press the or button to change the settingPress the or button to change the auto power off Setting Utility ModeConfirm that the device is switched off Check the Pressure AccuracyNon-Invasive Blood Pressure Nibp Measurement Non-Invasive Pressure Measurement PrinciplesSelecting the cuff Connecting the cuffCuff Selection and Connection Cuff name Arm circumference InchTo 2 cm Align the artery mark Index Artery with the brachial arteryMeasurement results are displayed Body movement detection function Taking the Measurement in Auscultation ModeIrregular pulse wave detection function Stopping the Measurement Displaying Last ReadingCleaning of the Device MaintenanceMaintenance Inspection and Safety Management Accessory CareAfter turning on the power Before turning on the powerWhen turning on the power Check before UseTroubleshooting Abnormal measurement value Measurement value is questionableMedium Internal hardware error Contact Omron Healthcare List of Error CodesError Priority Description Points to check Disposal Other problemsError Priority Cause Solution Code DescriptionTechnical Specifications HBP-1300 SpecificationsFactory Default Settings Power supplyEnvironmental Conditions Non-Invasive Blood Pressure NibpPage Manufacturer’s Declaration Emission Test Compliance Electromagnetic EnvironmentRecommend separation distance Separation distance according to frequency of transmitter Production facility ManufacturerEU-representative Subsidiary Omron Medizintechnik Handelsgesellschaft mbH