SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING
Service Indicator Light Diagnostics
NUMBER | ERROR CODE |
| |
OF | POSSIBLE SOLUTION | ||
DESCRIPTION | |||
FLASHES |
| ||
|
| ||
|
|
| |
1 | User Fault | Release joystick to neutral and try again. | |
|
|
| |
2 | Battery Fault | Charge the batteries. Refer to Charging Batteries on page 62. | |
|
| Check that battery cables are connected properly. If necessary, | |
|
| replace batteries. Refer to Replacing Batteries on page 55. | |
|
|
| |
3 | Left Motor Fault | Contact Invacare/Dealer for service. | |
|
|
| |
4 | Right Motor Fault | Contact Invacare/Dealer for service. | |
|
|
| |
5 | Left Park Brake Fault | Contact Invacare/Dealer for service. | |
|
|
| |
6 | Right Park Brake Fault | Contact Invacare/Dealer for service. | |
|
|
| |
7 | Remote Fault | Check to make sure joystick is connected properly. | |
|
| Contact Invacare/Dealer for service. | |
|
|
| |
8 | Controller Fault | Contact Invacare/Dealer for service. | |
|
|
| |
9 | Communications Fault | Contact Invacare/Dealer for service. | |
|
|
| |
10 | General Fault | Contact Invacare/Dealer for service. | |
|
|
| |
11 | Incompatible or incorrect | Wrong type of remote connected. Contact Invacare/Dealer | |
| Remote | for service. | |
|
|
|
MPJ™+, PSR+, PSF+ Joysticks or Displays
SYMPTOM | PROBABLE CAUSE | SOLUTIONS |
|
|
|
SPM L Park Brake Fault or | Motor lock levers disengaged | Engage motor lock levers. Refer to |
SPM R Park Brake Fault displays | (Error code E9 or E10). | Disengaging/Engaging Motor Lock |
| Levers on page 48. | |
and wheelchair does not drive. |
| |
|
| |
|
|
|
CHARGER PLUGGED IN displays. | Battery charger connected | Unplug battery charger from the |
| (Error code E28). | wheelchair. Refer to Charging Batteries |
|
| on page 62. |
|
|
|
SPM Battery Fault displays and the | Batteries need to be charged | Charge batteries. Refer to Charging |
wheelchair does not drive. | (Error code E14). | Batteries on page 62. If batteries fail to |
| charge properly, check battery charger | |
|
| |
|
| or replace batteries. Refer to Replacing |
|
| Batteries on page 55. |
|
|
|
JOYSTICK TIMEOUT displays and | Joystick or input device is | Turn off power, reconnect the joystick |
the wheelchair does not drive. | disconnected (Error code 32). | of input device and turn power on. |
|
| |
|
|
|
JS REV TOO LARGE | The joystick or input device is | Replace joystick or input device. |
JS FWD TOO LARGE | sending a value outside of the |
|
reverse, forward, left or right |
| |
JS LFT TOO LARGE or |
| |
limits (Error codes E01, E02, |
| |
JS RGT TOO LARGE | E03 or E04). |
|
displays and the wheelchair does not |
|
|
drive. |
|
|
|
|
|
Pronto® M51™ Base with SureStep® | 26 | Part No. 1148076 |