Clarity manual System Configuration two INT9 cards

Page 12

Clarity - INT9 A/D converter

Installation

2.4.2Using multiple INT9 cards

When using multiple A/D cards, it will be necessary to add the INT9 card again, repeating the entire procedure described in chapter 2.4 from Step 3.

Fig. 6. System Configuration – two INT9 cards

Individual detectors from all cards can be assigned to multiple instruments and combined together arbitrarily. In this example, all signals from INT7 A/D Card, as well as all signals from INT9 A/D Card 2 and one signal (Pressure) from INT9 A/D Card 1 are assigned to the instrument 1, while the rest of the signals from INT9 A/D Card 1 is assigned to the Instrument 2.

While there are several cards assigned to the same instrument, it is necessary to select which card will be used for Start and Ready

signals .

All added A/D converters (e.g. INT9) must have their drivers properly installed. There must be correct number of items in the Windows OS

12

Image 12
Contents Clarity Clarity Hardware Page Using multiple INT9 cards Using the INT9 card Brief Description INT9 Acquisition cardHardware and software requirements Advantages of the INT9 A/D converterInstallation Signal cablesINT9 Card Standard cable for Clarity stationConnection with Chromatograph Starting marker cablesDigital output cables Connecting Clarity to chromatograph Clarity configuration Select the DataApex INT9 A/D Card and pressSetup Control Modules list of the dialog DataApex INT9 A/D Card will appearSystem Configuration multiple Instruments System Configuration two INT9 cards Device Manager two INT9 cards Using the INT9 card INT9 A/D Card SetupNumber of Channels Inversion of Signal Channel 1 toName BipolarMethod Setup Supply FrequencySelect Detector RangeSample Rate External Start/Stop Start OnlyStart Restart Start StopDigital Inputs and Outputs DownTroubleshooting Locate your problemProblems with INT9 driver Board malfunctionHow to check the INT9 driver Error status of the driverManual Installation of the INT9 drivers Go to Start Programs Accessories System Tools System Restore Reinstallation of drivers in Windows Invoke the Start Control Panel Add/Remove Hardware Select Add/Troubleshoot a device and press the Next button Clarity directory. Then press the Next button Data Acquisition non-functional Data Acquisition Simulated Clarity INT9 A/D converter Troubleshooting Tables and specifications Description of the INT9 card connector MaleParameters of digital Inputs and Outputs INT9 CE Conformity Declaration Technical Data Input impedance Sample rate