Clarity INT9 manual Go to Start Programs Accessories System Tools System Restore

Page 24

Clarity - INT9 A/D converter

Troubleshooting

Select the Install from a list or specific location (Advanced) option.

Select Include this location in the search; here click the Browse button and select the path to the main folder of the workstation and INT subfolder (C:\CLARITY\HW_DRIVERS\INT9 by default).

Note: The driver is also located on the Clarity installation CD ROM in the HW_DRIVERS\INT9\XXX subfolder, where XXX is the type of your operating system. NT stands for Windows NT, while 2000 subdirectory contains drivers for Windows 2000, XP and Vista.

The rest of the installation will be carried out automatically.

4.3.2Reinstallation of drivers using the System Restore Point

Use the System Restore Point in MS Windows XP (and later) to uninstal the incorrect drivers.

Go to Start - Programs – Accessories – System Tools – System Restore.

24

Image 24
Contents Clarity Clarity Hardware Page Using multiple INT9 cards Using the INT9 card Brief Description INT9 Acquisition cardHardware and software requirements Advantages of the INT9 A/D converterInstallation Signal cablesINT9 Card Standard cable for Clarity stationConnection with Chromatograph Starting marker cablesDigital output cables Connecting Clarity to chromatograph Clarity configuration Select the DataApex INT9 A/D Card and pressSetup Control Modules list of the dialog DataApex INT9 A/D Card will appearSystem Configuration multiple Instruments System Configuration two INT9 cards Device Manager two INT9 cards Using the INT9 card INT9 A/D Card SetupNumber of Channels Inversion of Signal Channel 1 toName BipolarMethod Setup Supply FrequencySelect Detector RangeSample Rate External Start/Stop Start OnlyStart Restart Start StopDigital Inputs and Outputs DownTroubleshooting Locate your problemProblems with INT9 driver Board malfunctionHow to check the INT9 driver Error status of the driverManual Installation of the INT9 drivers Go to Start Programs Accessories System Tools System Restore Reinstallation of drivers in Windows Invoke the Start Control Panel Add/Remove Hardware Select Add/Troubleshoot a device and press the Next button Clarity directory. Then press the Next button Data Acquisition non-functional Data Acquisition Simulated Clarity INT9 A/D converter Troubleshooting Tables and specifications Description of the INT9 card connector MaleParameters of digital Inputs and Outputs INT9 CE Conformity Declaration Technical Data Input impedance Sample rate