Structure of the configuration menu of the SK 2015 transmitter
Transmitter must be switched off.
Simultaneously press SET+ON/OFF and keep both buttons pressed for 5 seconds
RESET
ON/OFF Cancels your entry on all levels of the
operating menu
SETUP
ACCESS
SET Releasing channels for the user
TUNE
SET |
|
|
|
|
|
|
|
| SET |
|
|
|
|
| |||
|
| 1.01 |
|
|
| 5.20 |
|
|
|
| ACCESS |
|
| ||||
|
|
|
|
|
|
|
| ||||||||||
|
| Displays |
|
|
| / : U.01...20, |
|
|
| Channel released: | |||||||
|
| channels that | 1.01...8.20, |
|
|
|
| "ACCESS" | is | ||||||||
|
| can be released |
|
|
| ERASE |
|
|
| displayed briefly | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Press SET |
| The next channel that |
|
|
|
| ||||||
|
|
|
|
|
|
| for 1 |
|
|
| |||||||
The selected channels are released |
| can be released is |
|
|
|
|
| ||||||||||
|
| displayed |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| STORED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SET |
|
|
|
|
|
|
| SET |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| U.01 |
|
|
| U.04 |
|
|
| 744.500 |
|
|
|
| 744.650 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Setting a |
|
|
| Current channel | / : U.01...20 | Current | / : Transmittion | |||||||
frequency for a |
|
|
|
|
|
|
|
|
|
| frequency of the | frequency tunable | ||
selected channel |
|
|
|
|
|
|
|
|
|
| selected | in steps of 25 kHz | ||
in the channel |
|
|
|
|
|
|
|
|
|
| channel | SET: Stores the | ||
bank "U" |
|
|
|
|
|
|
|
|
|
|
| setting | ||
|
|
|
|
|
|
|
|
|
| SET |
|
|
| |
|
|
|
|
| STORED |
|
|
|
|
|
|
|
| |
|
| SET |
|
|
|
|
|
|
|
|
| |||
NAME |
|
|
| SK 2015 |
|
| PETE15 |
|
|
|
| |||
Assigning a |
|
|
| Current name | / : Enter a name (6 characters) |
|
| |||||||
name |
|
|
|
|
|
|
|
| Letters w/o pronounciation marks, |
|
| |||
|
|
|
|
|
|
| SET | numbers from 0...9, special |
|
| ||||
|
|
|
|
|
|
|
|
| ||||||
|
|
| STORED |
| characters, spaces |
|
|
| ||||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| SET: 5 x next character, then store |
|
| ||
|
|
|
|
|
|
|
|
|
| the setting |
|
|
|
RESET
Loading the
SET
RST. NO
Confirmation
SET
RST. OK
/ | : OK |
|
SET: Unit loads | SET | |
default settings, unit is restarted, |
| |
| ||
"SETUP" display appears |
| |
/ | : NO |
|
SET: Reset is cancelled
SETUP
ACCESS
92