Sennheiser 2015 manual Additional information, Channel bank system, Range B, Range C

Page 46

Additional information

The channel bank system

The 2015 System is available in three UHF frequency ranges with 1,440 transmission/receiving frequencies per frequency range. Please note: Frequency usage is different for each country. Your Sennheiser agent will have all the necessary details on the available legal frequencies for your area.

Range A:

518 to 554 MHz

Range B:

626 to 662 MHz

Range C:

740 to 776 MHz

Transmitter and receiver have nine channel banks with up to 20 switchable channels each.

channel bank 1... 8

channel bank U

channel 1

 

preset frequency

 

 

 

 

channel 2

 

preset frequency

 

 

 

 

channel 20

 

preset frequency

 

 

 

 

channel 1

 

freely selectable frequency

 

 

 

 

 

 

 

channel 2

 

freely selectable frequency

 

 

 

 

 

 

 

channel 20

 

freely selectable frequency

 

Each of the channels in the channel banks “1” to “8” has been factory-preset to a transmission/receiving frequency (see enclosed frequency table). These frequencies are preset and cannot be changed as country- specific regulations on frequency usage are taken into account. The channel bank “U” (user bank) allows you to store your selection out of 1,440 transmission/receiving frequencies that are freely selectable within the preset frequency range.

An advantage of the factory-preset frequencies is that

ythe system is ready for immediate use after switch-on,

yseveral systems can be operated simultaneously on the preset channels of a channel bank without causing intermodulation interference.

98

Image 46
Contents Mikroport System 157 Bedienungsanleitung105 209Mikroport System Safety instructions Contents Warranty regulations 1022015 Mikroport System Operating principle of the 2015 Mikroport SystemMKE Delivery includes2015 EZB Transport case Transport holding device EZG Operating controls of the EK 2015 receiver Indications and displays on the receiver Battery status indicationAudio signal indication Alphanumeric displayDisplay for microphone level internal microphone Display for lock modeDisplay for the audio level Display for the RF levelOperating controls of the SK 2015 transmitter Mute indication Red LED flashing Battery pack or the batteriesIndications and displays on the transmitter Audio peak indicationDisplay for line level Display for microphone levelTransporting the transmitter and receiver Preparing the units for useTransport case Transport holding device How to properly use the battery pack or the batteries Connecting sound sources to the transmitterConnecting the microphones to the transmitter Attaching and positioning the microphones MKE ME 2015-HConnecting audio sources to the transmitter Connecting the receiver to hearing aids or headphonesConnecting the headphones Attaching the transmitter or receiver to clothing Wearing the transmitter or receiver around your neckSwitching the receiver on/off Using the receiverActivating/deactivating the lock mode Adjusting the level of the internal microphone Adjusting the level of the received audio signalSwitching the channel Displaying the frequency Operating menu of the EK 2015 receiver MICSwitching the transmitter on/off Using the transmitterMuting the microphone Activating/deactivating the lock mode Working with the transmitter’s operating menu Function of the buttonsSelecting a menu Adjusting a settingGetting into the operating menu Press the / rocker button UP/DOWN to select a menuOverview of menus Storing a settingExiting the operating menu Operating menu of the SK 2015 transmitter Operating menuAdjusting the microphone sensitivity Adjustment tips for the operating menu of the transmitterAdjusting the sensitivity of the line input Nel that is released on all receivers Switching between the channelsTion-free Troubleshooting Error checklistRecommendations and tips For the MKE 2015-0 plug-on microphone optional accessoryFor the ME 2015-H headset microphone optional accessory For system planningFor optimum reception Care and maintenanceFor multi-channel operation Configuration of the units by the technical expert Working with the configuration menuGetting into the configuration menu Exiting the configuration menu Structure of the configuration menu of the EK 2015 receiver ResetAccess Reset Adjusting the squelch threshold receiver only Adjustment tips for the configuration menuSwitching the internal microphone on or off receiver only Receiver onlyReleasing channels for the user Play Press the SET button and the button UP simultaneouslyThen displays the next channel that can be released Mitter and receiverResetting the unit to the factory-preset default settings Entering a nameClose the battery compartment Colored battery doors and face platesChanging the battery compartment cover Changing the face plate receiver onlyRange B Additional informationChannel bank system Range CRF link Inherent Noise of the RF link Transmitter HDX noise reduction systemYou can hear the difference Specifications Mikroport SystemEK 2015 receiver OFFSK 2015 transmitter Connector assignmentMm stereo jack plug, unbalanced Mm mono jack plug 102 System variants and accessories NT 3-US 104Garantiebestimmungen Conditions de garantie Garanzia prodottiDeclaración de garantia Page FCC DMOB2AUWG Observación BemerkungNota OpmerkingPage