QSC Audio MD-SP215, MD-LP115 Input/Output Connections, Gain Control, Filter Select Switch

Page 5

Input/Output Connections

The MD has a balanced 3-pin female XLR input marked IN and a male XLR output connector marked OUT. The IN and OUT connectors are wired in parallel, enabling connection of multiple enclosures in a “daisy-chain” fashion.

Balanced connections are recommended for less AC hum and interference, especially with long cable runs. Unbalanced connections may be suitable for short cables. The signal's source impedance should be less than 600 ohms.

Input connection

Insert the male XLR input into the jack marked IN. Ensure the connector is fully seated. The input impedance is 12k ohm balanced or 6k ohm unbalanced.

Balanced inputs: Connect to the plug as shown.

1= shield (ground)

3= minus (-) 2= plus (+)

Input (IN) and

Output (OUT)

Connectors

EN

Unbalanced inputs: Connect to the plug as shown. Pin 3 and pin 1 must be connected with a jumper as shown.

1= shield (ground)

3= jumper to pin 1 2= plus (+)

Output Connection

Insert the female XLR connector into the jack marked OUT. Connect the other end of the cable to the next down-stream audio device’s input connector.

Gain Control

The Gain control is recessed and can be adjusted with a small screwdriver or flat tool. Turn the gain control clockwise to increase gain and counter clockwise to decrease gain. The attenuation in dB (from maximum) is shown on the label.

The Gain control is marked in dB of attenuation. There are 21 detents for repeatable adjustments. The upper 14 steps are about 1 dB each, and settings should normally be made within this range. The range below -14 dB should not be used for normal program levels, as the input headroom could be exceeded, but can be used for testing at reduced levels. At the minimum setting, the signal is completely cut off.

Filter Select Switch

Above the Gain control is a small toggle switch that selects either Full Range input or applies a 100 Hz Hi-Cut filter to the input signal.

100 Hz Hi-Cut Setting (Lo-Pass Setting)

Engages an internal fourth-order crossover filter. It is designed to work with the 100 Hertz Lo-Cut filter on two- way, powered MD loudspeakers, forming an acoustically matched crossover without external processing.

Full Range Setting

Use the Full Range setting for applications with upstream filtering or signal processing. This allows tailoring of the sound to your tastes using your signal processing. The input signal must be appropriately processed for the enclosure (i.e. low frequency signal only). Do not apply a full-range audio input as the internal high-frequency protection circuit may shut down the amplifier.

Do not apply an input signal with high-frequency content when Full Range is selected!

Filter Select Switch

Gain Control

5

Image 5
Contents TD-000196-00 FCC Interference Statement Important Safety Precautions & Explanation of SymbolsMD-LP shown MD-SP similar InstallationIntroduction AC Mains Gain Control Filter Select SwitchInput/Output Connections LIM Limiter Indicator LED SIG Signal Indicator LEDDimensions MD-LP115 and MD-LP118 Dimensions MD-SP215 Dimensions MD-SP218 Pick Pointssures are not equipped with handles Location of Pick PointsAmp Power Input Sensitivity Input Headroom/Clipping SpecificationsMD-LP115 MD-LP118MD-SP215 Disclaimer QSC Audio Products 3 Year Limited WarrantyDeclaración de la FCC respecto a la interferencia ¡ADVERTENCIAInstalación IntroducciónLínea eléctrica de CA Instalación continuaciónConmutador de selección del filtro Conexiones de entrada/salidaControl de ganancia LED indicador LIM limitador LED indicador SIG señalDimensiones de los modelos MD-LP115 y MD-LP118 Page Ubicación de los puntos de suspensión Especificaciones 10’ 3m #18AWG y Garantía limitada de 3 años de QSC Audio Products RenunciaDéclaration de la FCC relative aux interférences Précautions importantes et explication des symbolesMD-LP en photo MD-SP similaire Alimentation secteur ~ Installation suiteSélecteur de filtre Commande de gainBranchements dentrée/de sortie Voyant LIM Limiteur Voyant SIG SignalDimensions MD-LP115 et MD-LP118 Dimensions MD-SP215 Dimensions MD-SP218 Points dattache Position des points dattacheMD-LP215 SpécificationsPoids Finition et grilleForgés 16 filets, 9,5 mm Remarques Puissance dampli Sensibilité dentréePoids 86,2 kg 95,3 kg Finition et grille QSC Audio Products Garantie limitée de 3 ans Avis de non-responsabilitéFCC-Hinweis zu Empfangsstörungen Wichtige Sicherheitsvorkehrungen und SymbolerklärungMD-LP abgebildet MD-SP ähnlich EinführungNetzanschluss Installation FortsetzungFilterauswahlschalter Eingangs-/AusgangsanschlüsseVerstärkungsregler LIM Limiter oder Begrenzer-Anzeige-LED SIG Signal-Anzeige-LEDAbmessungen MD-LP115 und MD-LP118 Abmessungen MD-SP215 Abmessungen MD-SP218 Befestigungspunkte Position der BefestigungspunkteSpezifikationen Gewicht Zoll 102 mm Schwingspule mitDemodulationsring aus Aluminium Beschränkte Dreijahresgarantie durch QSC Audio Products Haftungsausschluss重要的安全注意事项和符号说明 MD-LP 图示 (MD-SP 与此类同) 安装 (续) 输入 / 输出连接 信号指示 LED MD-LP115 和 MD-LP118 尺寸 MD-SP215 尺寸 MD-SP218 尺寸 起吊点位置 MD-LP115 MD-LP115 保修 (仅限美国;其它国家,请联系您的经销商或分销商)