QSC Audio MD-LP118, MD-LP115, MD-SP215 SIG Signal Indicator LED, LIM Limiter Indicator LED

Page 6

EN

SIG (Signal) Indicator LED

The green SIG (signal) indicator alerts the user to the presence of an input signal to the MD loudspeaker.

Normal Indication

The green SIG indicator illuminates when the input signal exceeds -25 dB.

If No Indication

Check Gain settings and increase gain if necessary. Check input connections and audio source for signal. If the red LIM LED illuminates, refer to the LIM indicator section, below.

Abnormal Indication

If the green SIG LED illuminates with no signal input, there may be system oscillations or some other malfunction. Disconnect the input or fully reduce the gain. If the green SIG LED remains on, the amp may need servicing.

LIM (Limiter) Indicator LED

The red LIM indicator alerts the user to several abnormal conditions within the MD loud- speaker:

Continuous Bright Red Light

Indicates protective mute mode.

The speaker normally mutes for several seconds after applying power, after which the light should go out, and sound should be heard.

If the speaker enters Mute during operation, it has either overheated or developed a fault.

Overheating should correct itself within 1-2 minutes, after which sound should resume. See below for a full explanation of thermal protection.

Short periods of muting could indicate excessive high-frequency program with subwoofer set at Full-Range. If this is not the case, it could indicate a component fault; remove AC power and have the speaker serviced.

Momentary Bright Red Flashes

During operation, bright flashing indicates clipping (overdrive distortion).

This is normally due to excessive volume, and will likely be accompanied by audible distortion.

If the speaker mutes repeatedly during peaks, there may be a component fault. AC power should be removed and the speaker serviced.

Continuous Half-Bright Light

Indicates that the internal limiter is reducing gain, due to prolonged clipping and/or excessive temperature.

After several seconds of severe clipping, the limiter will reduce power to protect the speaker and improve the sound. This results in a steady, half-bright red indication. Any further clipping will still result in bright flashes on top of the steady half-bright indication. When the program level is reduced, the limiter will clear after several seconds, and the red indicator will go out.

If the power module overheats despite fan operation, the first response is to trigger limiting, to reduce volume and limit further temperature rise. This results in a steady half-bright illumination that does not clear even after reducing program level. It may take several minutes for tempera- ture to drop and clear the limiter. During this time, the exposed heat sink will feel uncomfortably hot to the touch and the fan should be running. If overheating continues, the amplifier will ulti- mately mute, resulting in a full-bright red indication. When muting clears, the amplifier will resume operation, with thermal limiting still active until it further cools off.

Overheating is usually caused by excessive ambient temperature, since the internal temperature rise of the Class-D power module is relatively low. Protect the speaker from excessive tempera- tures, such as being placed over a heater vent, or allowing direct sunlight to impinge upon the heat sink surface.

SIG (signal) indicator LED

LIM (limiter) indicator LED

6

Image 6
Contents TD-000196-00 Important Safety Precautions & Explanation of Symbols FCC Interference StatementInstallation IntroductionMD-LP shown MD-SP similar AC Mains Filter Select Switch Input/Output ConnectionsGain Control SIG Signal Indicator LED LIM Limiter Indicator LEDDimensions MD-LP115 and MD-LP118 Dimensions MD-SP215 Dimensions MD-SP218 Location of Pick Points Pick Pointssures are not equipped with handlesMD-LP115 SpecificationsAmp Power Input Sensitivity Input Headroom/Clipping MD-LP118MD-SP215 QSC Audio Products 3 Year Limited Warranty Disclaimer¡ADVERTENCIA Declaración de la FCC respecto a la interferenciaIntroducción InstalaciónInstalación continuación Línea eléctrica de CAConexiones de entrada/salida Control de gananciaConmutador de selección del filtro LED indicador SIG señal LED indicador LIM limitadorDimensiones de los modelos MD-LP115 y MD-LP118 Page Ubicación de los puntos de suspensión Especificaciones 10’ 3m #18AWG y Renuncia Garantía limitada de 3 años de QSC Audio ProductsPrécautions importantes et explication des symboles Déclaration de la FCC relative aux interférencesMD-LP en photo MD-SP similaire Installation suite Alimentation secteur ~Commande de gain Branchements dentrée/de sortieSélecteur de filtre Voyant SIG Signal Voyant LIM LimiteurDimensions MD-LP115 et MD-LP118 Dimensions MD-SP215 Dimensions MD-SP218 Position des points dattache Points dattachePoids SpécificationsMD-LP215 Finition et grillePuissance dampli Sensibilité dentrée Poids 86,2 kg 95,3 kg Finition et grilleForgés 16 filets, 9,5 mm Remarques Avis de non-responsabilité QSC Audio Products Garantie limitée de 3 ansWichtige Sicherheitsvorkehrungen und Symbolerklärung FCC-Hinweis zu EmpfangsstörungenEinführung MD-LP abgebildet MD-SP ähnlichInstallation Fortsetzung NetzanschlussEingangs-/Ausgangsanschlüsse VerstärkungsreglerFilterauswahlschalter SIG Signal-Anzeige-LED LIM Limiter oder Begrenzer-Anzeige-LEDAbmessungen MD-LP115 und MD-LP118 Abmessungen MD-SP215 Abmessungen MD-SP218 Position der Befestigungspunkte BefestigungspunkteSpezifikationen Zoll 102 mm Schwingspule mit Demodulationsring aus AluminiumGewicht Haftungsausschluss Beschränkte Dreijahresgarantie durch QSC Audio Products重要的安全注意事项和符号说明 MD-LP 图示 (MD-SP 与此类同) 安装 (续) 输入 / 输出连接 信号指示 LED MD-LP115 和 MD-LP118 尺寸 MD-SP215 尺寸 MD-SP218 尺寸 起吊点位置 MD-LP115 MD-LP115 保修 (仅限美国;其它国家,请联系您的经销商或分销商)