5.Press A a third time to set the group to
Priority 1. A is displayed on line three. The priority level section sequence only advances the group to the next high priority level and stops at priority level 1. To select a lower priority level, the group must be deleted from the scan list and then added back to the scan list. Each new group added to the scan list starts at the lowest priority. If the priority 1 and Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously assigned group will change to
SCAN DIS The radio is not programmed to scan.
FIXED P1 A Priority 1 group has been pre- programmed into the radio. A new Priority 1 group cannot be selected.
FIXD LST A fixed scan list has been pre- programmed into the radio. It is not possible to change the list without reprogramming the radio.
Note: To quickly view multiple group scan status, press A then slowly but consistently
rotate the group knob. Each group status will appear on the display.
42