OPERATION

B-5

Return to Section TOC

Return to Section TOC

MEANING OF GRAPHICAL SYMBOLS ON RATING PLATE (LOCATED ON CASE BACK)

Designates welder complies with National Electrical Manufacturers NEMA EW 1 (100%) Association requirements EW 1 Class I with 100% duty cycle at

600Amps output.

Three Phase Input Power

3 Phase transformer with recti- fied DC output

Line Connection

MEANING OF GRAPHICAL SYMBOL FOR GROUND CON- NECTION

Signifies the equipment connection point for the protective earth ground

CONTROLS AND SETTINGS

All operator controls and adjustments are located on the Case Front Assembly of the DC-600. See Figure B.1 for the location of each control.

5

3

6

8

9

4

 

 

 

 

 

7

 

5

6

 

1

 

4

 

 

 

 

 

7

 

 

 

 

 

 

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

R

NRTL/C

Gas Metal Arc Welding (GMAW)

Flux Cored Arc Welding (FCAW)

Shielded Metal Arc Welding (SMAW)

Submerged Arc Welding (SAW)

Designates welder complies with both Underwriters Laboratories (UL) standards and Canadian Standards Association (CSA) standards. (60 Hertz Models)

3

 

8

 

2

 

9

 

1

 

10

 

DC-600

2

 

 

11

 

10

12

 

 

13

FIGURE B.1 - CONTROL PANEL KEYS

1.Input POWER ON/OFF Switch

This toggle switch turns the machine on or off.

Putting the switch in the ON “

” position ener-

gizes the machine’s input contactor applying input power to the machine. Switching the switch to the

OFF “ ” position de-energizes the input con- tactor.

2.POWER Light

When the POWER switch is in the ON position the machine’s white POWER light will illuminate. If the input contactor de-energizes the machine in an abnormal situation the pilot light will still illuminate. In this situation it may be necessary to reset the machine by switching the POWER switch to the OFF and then to the ON position. (See Overload, Overcurrent, and Fault Protection Section)

DC-600

Image 23
Contents DC-600 ISAFETYi Can be dangerous SafetyElectric Shock can kill Fumes and GasesFor Electrically Powered equipmentSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Master Table of Contents for ALL Sections Table of Contents Installation Section Technical Specifications DC-600 InstallationSelect Proper Location Safety PrecautionsElectric Shock can Kill Ground Connection Fuse and Wire SizesElectrical Input Connections Connection for Highest Rating Plate VOLTAGE, 50 or 60 HZ Reconnect ProcedureConnection for 440 Volts 50 or 60 HZ V 60HZ See Machine Rating Plate for Required Input Supply Voltage Connections Output ConnectionsELECTRODE, Work and #21 Lead Terminal Strip 2 T.S.2 Auxiliary Power Control ConnectionsTerminal Strip 1 T.S.1 DC-600 Table of Contents Operation Section Operation Safety PrecautionsRecommended Processes and Equipment Design Features AdvantagesGeneral Description Output Control Output Voltage Current Meanings of Graphical Symbols on Case FrontOFF Input Power Welding CapabilityControls and Settings Meaning of Graphical Symbol for Ground CON- NectionOVERLOAD, OVERCURRENT, and Fault Protection Auxiliary Power in MS-RECEPTACLEOperating Steps Remote Control of Machine OperationWelding Procedure Recommendations Remote NA-3 Automatic Wire FeederLN-7 and Other Constant Wire Feeders LN-8 or LN-9 SEMI-AUTOMATIC Wire FeederDC-600 Table of Contents Accessories Section Field Installed Options AccessoriesWire Feeders and Tractors Factory or Field Installed OptionsFigure C.2 MULTI-PROCESS Switch Cable Connections Accessories Table of Contents Maintenance Section Routine and Periodic Maintenance MaintenanceSafety Precautions Electric Shock can Kill 1TABLE of CONTENTS-THEORY of Operation Section E-1 Input Circuit and Main TRANS- Former Theory of OperationFiring Board Firing CIRCUIT, Control CIR- Cuit and RectificationRectification Thermal Protection SCR Operation DC-600 1TABLE of Contents Troubleshooting and Repair F-1 HOW to USE Troubleshooting Guide 2TROUBLESHOOTING and REPAIRF-2PC Board Troubleshooting Procedures Troubleshooting and RepairControl Feeder. See Protective Devices Check all three phase input Output Control J1,Pin2. See Wiring Diagram Wiring Diagram Materials Needed PC Board Troubleshooting GuideTest Description PC Board Troubleshooting Guide Figure F.2 Control Board LEDs Control BoardDC-600 Internal Trigger Circuit Test Internal Trigger Circuit Test Procedure75 76 Internal Trigger Circuit TestDC-600 Firing Board Test Firing Board Test Control Board Test Figure F.7 Control Board Control Board TestMain Transformer Voltage Test Figure F.8 Input Contactor and Reconnect Panel Main Transformer Voltage TestFigure F.9 Transformer Secondaries Main Transformer Voltage Test Control Transformer Test Control Transformer Test ProcedureInput Contactor Test Voltage Test Input Contactor TestSCR Bridge Test SCR Bridge Test Anode Cathode Remove Insulating PaintActive Test Scope Settings Maximum Output Setting no Load Minimum Output Setting no Load 35TROUBLESHOOTING and REPAIRF-35 2V/Div Volts DC-600 Input Contactor CR1 CLEANING/REPLACEMENT Contactor Replacement Procedure Input Contactor CLEANING/REPLACEMENT ProcedureCleaning Procedure SCR Rectifier Bridge Removal and Replacement Procedure SCR Rectifier Bridge 42TROUBLESHOOTING and REPAIRF-42Removal and Replacement Procedure Removal ProcedureInsulator Lock Washer Plain Washer Output Snubber Lead Replacement ProcedureDC-600 Main Transformer and Choke Removal and Replacement Main Transformer and Choke Removal and ReplacementRemoval Procedure Weld Maximum Open Circuit Voltages Input Idle Amps and WattsDC-600 Table of Contents Diagram Section Electrical Diagrams Wiring Diagram 230/460/575 Volt Machines G3506-1 Schematic Complete Machine G3575 Schematic Control PC Board G3408-1 Control PC Board Assembly G3409-1 Schematic Firing PC Board G3741-1