TROUBLESHOOTING AND REPAIR |
|
| ||||||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
| PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED |
| ||
| (SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION | |||
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
Poor arc starting when the DC600 is | 1. | Make sure the proper welding | 1. | Check the connections from the | ||||
in the CV |
| procedures are being used. |
| shunt to the Control Board | ||||
Modes. |
|
| (wire feed speed, arc voltage |
| (leads 210 and 215). When weld | |||
|
|
| and wire size) |
| current is present there should | |||
|
| 2. Check weld cables for loose or |
| be a millivolt signal at the board | ||||
|
|
| (6.25mv/100 amps). |
| ||||
|
|
| faulty connections. |
|
|
|
|
|
|
|
|
| 2. Perform the Firing Board Test. | ||||
|
|
|
| 3. | Perform | the | SCR | Output |
|
|
|
|
| Bridge Test. |
|
| |
|
|
|
| 4. The Control | Board | may be | ||
|
|
|
|
| faulty. |
|
|
|
|
|
|
|
| ||||
Poor arc characteristics in all | 1. | Check for the correct input volt- | 1. | Check the Mode Switch (SW4) | ||||
processes. |
|
| ages on the three phase input |
| and the associated wiring for | |||
|
|
| lines at the DC600. |
| loose or faulty connections. See | |||
|
|
|
|
| the Wiring Diagram. |
| ||
|
| 2. Make sure the proper welding |
|
|
|
|
| |
|
|
| procedures are being used (wire | 2. | Check the voltage at the shunt | |||
|
|
| feed speed, arc voltage and wire |
| (leads 210 and 215). When weld | |||
|
|
| size). |
| current is present there should | |||
|
|
|
|
| be a millivolt signal at the board | |||
|
| 3. | Check the welding cables for |
| (6.25mv/100 amps). If not cor- | |||
|
|
| loose or faulty connections. |
| rect, the shunt may be defective | |||
|
|
|
| 3. Perform the Firing Board Test. | ||||
|
|
|
| 4. | Perform | the | SCR | Output |
|
|
|
|
| Bridge test. |
|
| |
|
|
|
| 5. The Control | Board | may be | ||
|
|
|
|
| faulty. |
|
|
|
|
|
|
|
|
|
|
|
|