TROUBLESHOOTING AND REPAIR

 

 

F-5

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

Input contactor pulls in when

1.

Make sure input line voltage

1. I f c o n t a c t o r ( C R 1 )

f u n c t i o n s

ON/OFF Switch is closed but imme-

 

matches machine rating and the

c o r r e c t l y w i t h t h e c a bl e s

diately drops out.

 

reconnect panel is connected

removed there may be a fault in

 

 

 

correctly for the line voltage.

the control cables or the wire

 

 

 

 

 

 

feeder. See Protective Devices

 

 

 

Remove all weld cables and

and Shutdown Circuits.

 

 

 

 

external wires attached to termi-

2. Check inter nal remote control

 

 

 

nal strip and the 14pin MS con-

 

 

 

c i r c u i t ( l e a d s 7 5 , 7 6 a n d 7 7 )

 

 

 

nector

and make sure

the

 

 

 

including the Output Terminals

 

 

 

Output

Terminals Switch

is in

 

 

 

S w i t c h ( S 3 ) a n d t h e O u t p u t

 

 

 

the REMOTE position.

 

 

 

 

 

C o n t r o l ( R 1 ) fo r gr o u n d s o r

 

 

 

 

 

 

 

 

2. If the problem persists after per-

s h o r t s. S e e t h e

Wiring

 

 

Diagram.

 

 

 

 

 

 

forming step 1 the problem is in

 

 

 

 

 

 

 

 

 

 

 

 

 

the DC600.

 

4. The Control Board may be

 

 

 

 

 

 

 

 

 

 

 

 

faulty. See the PC Board

 

 

 

 

 

 

Troubleshooting Guide.

 

 

 

 

 

Machine shuts off (input contactor

1.

Remove all welding cables and

1. Check for grounds and or shorts

drops out) when the welder output

 

control cables from the DC 600.

in the #75, #76, #77 circuit. See

terminals

are made electrically

 

If the machine does NOT shut

the Wiring Diagram.

 

"hot".

 

 

off and normal open circuit volt-

 

 

 

 

(Output Terminals Switch ON).

 

age is present at the welder out-

2. Check for grounds and shorts in

 

 

 

put terminals the problem is

the welder output terminals and

 

 

 

external to the DC600. Either

associated

leads.

See

the

 

 

 

the remote leads #75, #76 or

Wiring Diagram.

 

 

 

 

 

#77 are grounded to the nega-

 

 

 

 

 

 

 

tive output circuit or there is a

3. Check the

output

shunt

and

 

 

 

short on the welding output ter-

associated

leads.

See

the

 

 

 

minals.

 

 

Wiring Diagram.

 

 

 

 

2.

If the machine still shuts off

4. Perform the Control Board

 

 

 

when all control and welding

Test.

 

 

 

 

 

 

cables are removed then the

 

 

 

 

 

 

 

problem is internal to the

 

 

 

 

 

 

 

DC600.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

DC-600

Image 45
Contents DC-600 ISAFETYi Electric Shock can kill SafetyFumes and Gases Can be dangerousFor Electrically Powered equipmentSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Master Table of Contents for ALL Sections Table of Contents Installation Section Technical Specifications DC-600 InstallationSafety Precautions Electric Shock can KillSelect Proper Location Fuse and Wire Sizes Electrical Input ConnectionsGround Connection Connection for Highest Rating Plate VOLTAGE, 50 or 60 HZ Reconnect ProcedureConnection for 440 Volts 50 or 60 HZ V 60HZ See Machine Rating Plate for Required Input Supply Voltage Output Connections ELECTRODE, Work and #21 LeadConnections Auxiliary Power Control Connections Terminal Strip 1 T.S.1Terminal Strip 2 T.S.2 DC-600 Table of Contents Operation Section Operation Safety PrecautionsDesign Features Advantages General DescriptionRecommended Processes and Equipment OFF Input Power Meanings of Graphical Symbols on Case FrontWelding Capability Output Control Output Voltage CurrentControls and Settings Meaning of Graphical Symbol for Ground CON- NectionOVERLOAD, OVERCURRENT, and Fault Protection Auxiliary Power in MS-RECEPTACLERemote Control of Machine Operation Welding Procedure RecommendationsOperating Steps Remote NA-3 Automatic Wire FeederLN-7 and Other Constant Wire Feeders LN-8 or LN-9 SEMI-AUTOMATIC Wire FeederDC-600 Table of Contents Accessories Section Wire Feeders and Tractors AccessoriesFactory or Field Installed Options Field Installed OptionsFigure C.2 MULTI-PROCESS Switch Cable Connections Accessories Table of Contents Maintenance Section Maintenance Safety Precautions Electric Shock can KillRoutine and Periodic Maintenance 1TABLE of CONTENTS-THEORY of Operation Section E-1 Input Circuit and Main TRANS- Former Theory of OperationFiring CIRCUIT, Control CIR- Cuit and Rectification RectificationFiring Board Thermal Protection SCR Operation DC-600 1TABLE of Contents Troubleshooting and Repair F-1 HOW to USE Troubleshooting Guide 2TROUBLESHOOTING and REPAIRF-2PC Board Troubleshooting Procedures Troubleshooting and RepairControl Feeder. See Protective Devices Check all three phase input Output Control J1,Pin2. See Wiring Diagram Wiring Diagram PC Board Troubleshooting Guide Test DescriptionMaterials Needed PC Board Troubleshooting Guide Figure F.2 Control Board LEDs Control BoardDC-600 Internal Trigger Circuit Test Internal Trigger Circuit Test Procedure75 76 Internal Trigger Circuit TestDC-600 Firing Board Test Firing Board Test Control Board Test Figure F.7 Control Board Control Board TestMain Transformer Voltage Test Figure F.8 Input Contactor and Reconnect Panel Main Transformer Voltage TestFigure F.9 Transformer Secondaries Main Transformer Voltage Test Control Transformer Test Control Transformer Test ProcedureInput Contactor Test Voltage Test Input Contactor TestSCR Bridge Test SCR Bridge Test Anode Cathode Remove Insulating PaintActive Test Scope Settings Maximum Output Setting no Load Minimum Output Setting no Load 35TROUBLESHOOTING and REPAIRF-35 2V/Div Volts DC-600 Input Contactor CR1 CLEANING/REPLACEMENT Input Contactor CLEANING/REPLACEMENT Procedure Cleaning ProcedureContactor Replacement Procedure SCR Rectifier Bridge Removal and Replacement Procedure Removal and Replacement Procedure 42TROUBLESHOOTING and REPAIRF-42Removal Procedure SCR Rectifier BridgeInsulator Lock Washer Plain Washer Output Snubber Lead Replacement ProcedureDC-600 Main Transformer and Choke Removal and Replacement Main Transformer and Choke Removal and ReplacementRemoval Procedure Weld Maximum Open Circuit Voltages Input Idle Amps and WattsDC-600 Table of Contents Diagram Section Electrical Diagrams Wiring Diagram 230/460/575 Volt Machines G3506-1 Schematic Complete Machine G3575 Schematic Control PC Board G3408-1 Control PC Board Assembly G3409-1 Schematic Firing PC Board G3741-1