TROUBLESHOOTING AND REPAIR |
|
| ||||||||||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| |||||
| PROBLEMS |
| POSSIBLE AREAS OF |
|
| RECOMMENDED |
| |||||
| (SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
| ||||||
|
|
|
|
|
|
|
|
|
| |||
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
| |||
The Machine is dead - The Input | 1. | Check | for blown | or missing | 1. | The ON/OFF Switch | (S1) may | |||||
contactor does not operate. |
| fuses in input lines. |
|
| be faulty |
|
|
| ||||
|
| 2. Check the three phase input line | 2. | The | Control Transformer | (T2) | ||||||
|
|
| voltage | at the | machine. The |
| may | be faulty. | Perform | the | ||
|
|
| input voltage must match the |
| Control Transformer Test. |
| ||||||
|
|
| rating | plate | and | reconnect |
|
|
|
|
|
|
|
|
| panel. |
|
|
| 3. | The primary or secondary ther- | ||||
|
|
|
|
|
|
|
| mostats may be open. Check or | ||||
|
|
|
|
|
|
|
| replace. Also check the associ- | ||||
|
|
|
|
|
|
|
| ated wiring. See the Wiring | ||||
|
|
|
|
|
|
|
| Diagram. |
|
|
| |
|
|
|
|
|
|
| 4. | The pilot relay (CR2) may be | ||||
|
|
|
|
|
|
|
| faulty. Check or replace. |
| |||
|
|
|
|
|
|
| 5. | The input contactor coil may be | ||||
|
|
|
|
|
|
|
| open. |
|
|
| |
|
|
|
|
|
|
| 6. | The Control Board may be | ||||
|
|
|
|
|
|
|
| faulty. Perform | the | Control | ||
|
|
|
|
|
|
|
| Board Test. |
|
|
| |
|
|
|
|
| ||||||||
Input contactor (CR1) chatters. | 1. | The input line voltage may be | 1. | The pilot relay (CR2) may have | ||||||||
|
|
| low. Check all three phases. |
| bad contacts. Check or replace | |||||||
|
|
|
|
|
|
|
| relay. |
|
|
| |
|
| 2. Make sure input line voltage | 2. | Check for loose or faulty wiring | ||||||||
|
|
| matches machine rating and the | |||||||||
|
|
| reconnect panel is | connected |
| between pilot relay (CR2) and | ||||||
|
|
| correctly for the line voltage |
| input contactor (CR1) coil con- | |||||||
|
|
|
|
|
|
|
| nections.See Wiring Diagram. | ||||
|
|
|
|
|
|
| 3. | The input contactor (CR1) may | ||||
|
|
|
|
|
|
|
| be |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call