TROUBLESHOOTING AND REPAIR |
|
|
|
| ||||||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||||
PROBLEMS |
|
| POSSIBLE AREAS OF |
| RECOMMENDED |
| ||||
(SYMPTOMS) |
|
| MISADJUSTMENT(S) |
| COURSE OF ACTION | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
|
|
Machine has maximum weld output | 1. | If remote control is being used | 1. | Check | the | LOCAL/REMOTE | ||||
and no control. |
|
| set LOCALl/REMOTE SWITCH |
| Switch (SW3) | and | associated | |||
|
|
| (SW3) to ‘LOCAL’ position and |
| wiring. |
|
|
|
|
|
|
|
| try to control weld output using |
|
|
|
|
|
|
|
|
|
| the Output Control | 2. | Check | feedback leads #222 | ||||
|
|
| Potentiometer (R1) at the |
| (negative | output | terminal), | |||
|
|
| DC600. If the problem is solved |
| #215, and | #210 (output shunt) | ||||
|
|
| check the remote control unit |
| for loose or faulty connections. | |||||
|
|
| (or wire feeder) and associated |
| See Wiring Diagram. |
| ||||
|
|
| control cable. |
|
|
|
|
|
|
|
|
|
|
| 3. Check the #75 lead for continu- | ||||||
|
|
|
|
| ity (zero ohms) from the Output | |||||
|
|
|
|
| Control | Potentiometer | (R1) to | |||
|
|
|
|
| the control board | connector | ||||
|
|
|
|
| J1,Pin2. See Wiring Diagram. | |||||
|
|
|
| 4. | Possible | defective |
| Control | ||
|
|
|
|
| Board or Firing Board. See the | |||||
|
|
|
|
| PC Board | Troubleshooting | ||||
|
|
|
|
| Guide. |
|
|
|
|
|
|
|
|
| 5. | Perform | the | SCR | Output | ||
|
|
|
|
| Bridge Test. |
|
|
| ||
|
|
|
|
|
|
|
| |||
Machine has minimum output and | 1. | If a remote control unit is NOT | 1. | Check | the | Output | Control | |||
no control. |
|
| connected to the |
| Potentiometer (R1) and associ- | |||||
|
|
| LOCAL/REMOTE Switch must |
| ated wiring. |
|
|
|
| |
|
|
| be in the "LOCAL" position. |
|
|
|
|
|
|
|
|
|
|
| 2. | Check | the | LOCAL/REMOTE | |||
|
| 2. If a remote control cable is con- |
| Switch (SW3), the Weld Mode | ||||||
|
|
| nected, the control leads may |
| Switch (SW4) | and | associated | |||
|
|
| be "shorted" to the positive weld |
| wiring. |
|
|
|
|
|
|
|
| output. |
|
|
|
|
|
|
|
|
|
|
| 3. | Perform | the | Control | Board | ||
|
| 3. | Make certain the three phase |
| Test. |
|
|
|
|
|
|
|
| input voltage is correct and |
|
|
|
|
|
|
|
|
|
| matches the machine rating and | 4. | Perform the Firing Board Test. | |||||
|
|
| the reconnect panel. |
|
|
|
|
|
|
|
|
|
|
| 5. | Perform | the | SCR | Output | ||
|
|
|
|
| Bridge Test. |
|
|
| ||
|
|
|
| 6. Perform the Main Transformer | ||||||
|
|
|
|
| Test. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call