Lincoln Electric SVM188-A Firing CIRCUIT, Control CIR- Cuit and Rectification, Firing Board

Page 37

E-3

THEORY OF OPERATION

E-3

 

FIGURE E.2 - FIRING BOARD,CONTROL BOARD AND RECTIFICATION

 

Return to Section TOC

Return to Section TOC

CONTROL

POWER

TRANSFORMER

SWITCH

115VAC

 

Pilot

 

Light

w

 

CR2

 

Secondary

Thermostat

Primary

 

Theromstat

1CR Coil

 

 

R

 

E

 

C

 

O

 

N

 

N

 

E

 

C

 

T

CONTACTOR

CR1

 

 

 

 

 

 

 

TERMINAL

 

 

 

 

 

 

 

 

 

STRIP 1

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

FAULT PROTECTION

 

 

 

 

 

CONTROL

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

32VAC

 

 

 

 

OUTPUT

CONTROL

 

32VAC

 

 

FIRING

CONTROL SIGNAL

 

 

 

 

 

 

 

 

32VAC

 

 

BOARD

 

 

 

 

 

 

 

 

G

S

 

 

 

 

14-pin

115VAC

Fan

A

I

 

 

 

 

T

G

 

 

 

 

Amphenol

Receptacle

Motor

E

N

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

L

 

 

 

 

T

 

115VAC

 

 

 

 

CONTROL

 

 

S

 

 

 

 

 

 

 

R

 

 

 

 

BOARD

 

MODE

T

 

 

 

 

 

E

 

 

OUTPUT

 

 

 

 

 

SWITCH

I

I

 

 

 

 

 

 

M

R

 

 

 

 

 

 

 

 

N

P

TERMINAL

 

 

 

 

 

 

AL

2

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

F

 

 

42VAC

 

115VAC

 

 

 

 

E

 

 

 

 

 

 

 

 

 

E

 

 

MAIN

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

B

 

 

TRANSFORMER

 

 

 

 

A

 

 

 

 

 

 

 

 

 

C

 

POSITIVE

 

 

 

 

 

 

 

K

 

 

 

 

 

 

 

 

 

TERMINAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUNT

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

LATCHING

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESISTOR

B

 

 

 

 

 

SCR BRIDGE

 

A

 

 

 

 

 

 

C

NEGATIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHOKE

 

K

TERMINAL

 

 

 

 

 

 

 

 

Return to Section TOC

Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Master TOC

FIRING CIRCUIT, CONTROL CIR- CUIT AND RECTIFICATION

RECTIFICATION

The “neutrals” of the welding secondary windings in the main transformer are connected together, and the six starts are connected to the six Silicon Controlled Rectifier (SCR) assemblies to form a six-phase output. This six-phase AC output from the main transformer secondary is rectified and controlled by the SCR bridge.

FIRING BOARD

The firing board is powered by the three-phase 32vac transformer windings. Each phase provides two firing pulses, one for each of the two SCRs controlled by that phase. When a gate firing enable*(trigger) signal is received, the firing circuit supplies the proper amount of energy to the gates of the power SCRs. When this gate firing signal is applied at the correct time, the SCR will turn ON. The amount of ON time versus OFF time determines the output of the machine. See SCR Operation. At the same time the latching resistor is connected across the machine’s output circuit. The latching resistor provides a pre-load for the SCR bridge so the SCR’s will stay activated providing open circuit voltage (OCV).

CONTROL BOARD

The control board receives current feedback informa- tion from the shunt and voltage feedback information from the choke and welding output terminals. This feedback information is processed on the control board. The control board compares the commands of the mode switch, the output control potentiometer (or remote control device) and the arc force control with the feedback information and sends the appropriate output control signal to the firing board. In the event of a “fault condition,” the control board de-activates the fault relay (CR2). See Protective Devices and Shut Down Circuits.

An output choke is connected between the neutral con- nection of the main transformer secondaries and the negative output terminal. This large inductor stores energy, and provides current filtering for the welding output of the DC-600.

*Triggering is accomplished by a connection of lead #2 & #4 by way of the Output Terminal Switch or by a remote signal from a wire feeder. The 2 to 4 closure is indicated by LED10 on the firing Board and LED 6 on the Control Board.

Return to

Return to

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion

DC-600

Image 37
Contents DC-600 ISAFETYi Electric Shock can kill SafetyFumes and Gases Can be dangerousFor Electrically Powered equipmentSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Master Table of Contents for ALL Sections Table of Contents Installation Section Technical Specifications DC-600 InstallationElectric Shock can Kill Safety PrecautionsSelect Proper Location Electrical Input Connections Fuse and Wire SizesGround Connection Connection for Highest Rating Plate VOLTAGE, 50 or 60 HZ Reconnect ProcedureConnection for 440 Volts 50 or 60 HZ V 60HZ See Machine Rating Plate for Required Input Supply Voltage ELECTRODE, Work and #21 Lead Output ConnectionsConnections Terminal Strip 1 T.S.1 Auxiliary Power Control ConnectionsTerminal Strip 2 T.S.2 DC-600 Table of Contents Operation Section Operation Safety PrecautionsGeneral Description Design Features AdvantagesRecommended Processes and Equipment OFF Input Power Meanings of Graphical Symbols on Case FrontWelding Capability Output Control Output Voltage CurrentControls and Settings Meaning of Graphical Symbol for Ground CON- NectionOVERLOAD, OVERCURRENT, and Fault Protection Auxiliary Power in MS-RECEPTACLEWelding Procedure Recommendations Remote Control of Machine OperationOperating Steps Remote NA-3 Automatic Wire FeederLN-7 and Other Constant Wire Feeders LN-8 or LN-9 SEMI-AUTOMATIC Wire FeederDC-600 Table of Contents Accessories Section Wire Feeders and Tractors AccessoriesFactory or Field Installed Options Field Installed OptionsFigure C.2 MULTI-PROCESS Switch Cable Connections Accessories Table of Contents Maintenance Section Safety Precautions Electric Shock can Kill MaintenanceRoutine and Periodic Maintenance 1TABLE of CONTENTS-THEORY of Operation Section E-1 Input Circuit and Main TRANS- Former Theory of OperationRectification Firing CIRCUIT, Control CIR- Cuit and RectificationFiring Board Thermal Protection SCR Operation DC-600 1TABLE of Contents Troubleshooting and Repair F-1 HOW to USE Troubleshooting Guide 2TROUBLESHOOTING and REPAIRF-2PC Board Troubleshooting Procedures Troubleshooting and RepairControl Feeder. See Protective Devices Check all three phase input Output Control J1,Pin2. See Wiring Diagram Wiring Diagram Test Description PC Board Troubleshooting GuideMaterials Needed PC Board Troubleshooting Guide Figure F.2 Control Board LEDs Control BoardDC-600 Internal Trigger Circuit Test Internal Trigger Circuit Test Procedure75 76 Internal Trigger Circuit TestDC-600 Firing Board Test Firing Board Test Control Board Test Figure F.7 Control Board Control Board TestMain Transformer Voltage Test Figure F.8 Input Contactor and Reconnect Panel Main Transformer Voltage TestFigure F.9 Transformer Secondaries Main Transformer Voltage Test Control Transformer Test Control Transformer Test ProcedureInput Contactor Test Voltage Test Input Contactor TestSCR Bridge Test SCR Bridge Test Anode Cathode Remove Insulating PaintActive Test Scope Settings Maximum Output Setting no Load Minimum Output Setting no Load 35TROUBLESHOOTING and REPAIRF-35 2V/Div Volts DC-600 Input Contactor CR1 CLEANING/REPLACEMENT Cleaning Procedure Input Contactor CLEANING/REPLACEMENT ProcedureContactor Replacement Procedure SCR Rectifier Bridge Removal and Replacement Procedure Removal and Replacement Procedure 42TROUBLESHOOTING and REPAIRF-42Removal Procedure SCR Rectifier BridgeInsulator Lock Washer Plain Washer Output Snubber Lead Replacement ProcedureDC-600 Main Transformer and Choke Removal and Replacement Main Transformer and Choke Removal and ReplacementRemoval Procedure Weld Maximum Open Circuit Voltages Input Idle Amps and WattsDC-600 Table of Contents Diagram Section Electrical Diagrams Wiring Diagram 230/460/575 Volt Machines G3506-1 Schematic Complete Machine G3575 Schematic Control PC Board G3408-1 Control PC Board Assembly G3409-1 Schematic Firing PC Board G3741-1