TROUBLESHOOTING AND REPAIR |
MAIN TRANSFORMER VOLTAGE TEST (continued)
FIGURE F.8 - INPUT CONTACTOR AND RECONNECT PANEL
L3 | T3 |
L2 | T2 |
L1 | T1 |
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
PROCEDURE
1.Disconnect the main input power from the
2.Inspect the input contactor, reconnect panel and primary leads to the main transformer for loose or faulty connections. See Figure F.8.
3.Confirm that the reconnect panel is configured cor- rectly for the
4.Connect the correct AC
WARNING
ELECTRIC SHOCK can kill.
•Do not touch electrically hot parts.
5.Turn the power switch (SW1) to the ON position.
6.Make sure the input contactor (CR1) energizes.
7.Test with an AC voltmeter for the proper main AC input voltages applied to the line side of the input contactor (CR1). See Figure F.8 .
a.L1 to L2
b.L2 to L3
c.L1 to L3
•If the voltages are not correct at the line side of the input contactor, check the input fuses and leads.
8.Test with an AC voltmeter for the proper AC input voltages at the output side of the input contactor (CR1). See Figure F.8.
a. T1 to T2 b. T2 to T3 c. T1 to T3
•If the correct voltages are not present, perform the Input Contactor Test.