TROUBLESHOOTING AND REPAIR |
RETEST AFTER REPAIR
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.
INPUT IDLE AMPS AND WATTS
Input volts/Phase/Hertz | Maximum Idle Amps | Maximum Idle KW |
208/3/60 | 11.0 | 1.0 |
230/3/60 | 10.0 | 1.0 |
380/3/60 | 6.0 | 1.0 |
416/3/60 | 5.5 | 1.0 |
460/3/60 | 5.0 | 1.0 |
550/3/60 | 4.2. | 1.0 |
575/3/60 | 4.0 | 1.0 |
200/3/50 | 21.0 | 1.3 |
220/3/50 | 19.1 | 1.3 |
230/3/50 | 18.3 | 1.3 |
380/3/50 | 11.0 | 1.3 |
400/3/50 | 10.5 | 1.3 |
415/3/50 | 10.1 | 1.3 |
440/3/50 | 9.6 | 1.3 |
500/3/50 | 8.4 | 1.3 |
550/3/50 | 7.7 | 1.3 |
MAXIMUM OPEN CIRCUIT VOLTAGES
Mode | Input Hertz | Open Circuit Volts |
CC Stick | 60 | 66/70 |
CV MIG | 60 | 44/47 |
Auxiliary Output | 60 | 122/128 VAC |
Auxiliary Output | 60 | 44/48 VAC |
MINIMUM ACCEPTABLE OUTPUT VOLTAGE - AT MAXIMUM OUTPUT SETTINGS
Mode | Control Settings | Load |
CC Stick | Output Control at Maximum | 815 Amps @ 44.0 Volts (Min) |
| Arc Force Control at |
|
| Minimum |
|
CV MIG | Output Control at Maximum | 815 Amps @ 44.0 Volts (Min) |
Auxiliary Output | N/A | 5 Amps @ 120/126 VAC (Min) |
Auxiliary Output | N/A | 5 Amps #41/45 VAC (Min) |