Lincoln Electric LN-10 manual Dual Procedure Remote Control K1449-1

Page 22

B-9

OPERATION

B-9

 

 

 

DUAL PROCEDURE REMOTE CONTROL (K1449-1)

When this option is connected to the LN-10 Control Box receptacle, and the Procedure Key selects “REMOTE” the front panel knob controls and proce- dure selection is transferred to the knob encoder con- trols and Procedure Selector Switch of the remote, which function in the exact same manner. Remote knob encoders set Weld voltage and wire feed speed, as well as Trigger Cold Feed Speed, but not Timers or Run-In.

If using the optional K683-1, -3 Dual Procedure Switch, for a wire drive, to select A or B along with the (K1449-1) remote, both the front panel and remote Procedure selector and switch must be set to “REMOTE” and “Gun Switch” (center) positions.

The LN-10 Procedure lights indicate whether A or B is remotely selected.

WIRE REEL LOADING - READI-REELS, SPOOLS OR COILS

To Mount a 30 Lb. (14 kg) Readi-Reel Package (Using the Molded Plastic K363-P Readi-Reel Adapter:)

The Spindle should be located in the LOWER mounting hole.

1)Depress the Release Bar on the Retaining Collar and remove it from the spindle.

2)Place the Adapter on the spindle.

3)Re-install the Retaining Collar. Make sure that the Release Bar “pops up” and that the collar retainers fully engage the retaining groove on the spindle.

4)Rotate the spindle and adapter so the retaining spring is at the 12 o'clock position.

5)Position the Readi-Reel so that it will rotate in a direction when feeding so as to be de-reeled from bottom of the coil.

6)Set one of the Readi-Reel inside cage wires on the slot in the retaining spring tab.

7)Lower the Readi-Reel to depress the retaining spring and align the other inside cage wires with the grooves in the molded adapter.

8)Slide cage all the way onto the adapter until the retaining spring "pops up" fully.

WARNING

Check to be sure the Retaining Spring has fully returned to the locking position and has SECURELY locked the Readi-Reel Cage in place. Retaining Spring must rest on the cage, not the welding elec- trode.

___________________________________________

9)To remove Readi-Reel from Adapter, depress retaining spring tab with thumb while pulling the Readi-Reel cage from the molded adapter with both hands. Do not remove adapter from spindle.

FIGURE B.1

To Mount 10 to 44 Lb. (4.5-20 kg) Spools (12"/300 mm Diameter) or 14Lb.(6 Kg) Innershield Coils:

The Spindle should be located in the LOWER mounting hole.

(For 8" (200 mm) spools, a K468 spindle adapter must first be slipped onto spindle.)

(For 13-14 lb. (6 Kg) Innershield coils, a K435 Coil Adapter must be used).

1)Depress the Release Bar on the Retaining Collar and remove it from the spindle.

2)Place the spool on the spindle making certain the spindle brake pin enters one of the holes in the back side of the spool. Be certain the wire comes off the reel in a direction so as to de-reel from the bottom of the coil.

3)Re-install the Retaining Collar. Make sure that the Release Bar “pops up” and that the collar retainers fully engage the retaining groove on the spindle.

LN-10

Image 22
Contents IM906 Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Recommended Processes and Equipment InstallationGeneral Description Available ModelsSeries Wire Drive Ratio Selection Wire Drive Speed Range SelectionControl Speed Range Setting Electrode RoutingProcedure to Install Drive Roll and Wire Guides Wire Feed Drive Roll KitsGUN and Cable Assemblies with Standard Connection Gun Cable Connection with Standard Connection Series Wire Drive Water Connections for Water Cooled GunsGUN and Cable Assemblies with FAST-MATE Connection Gun Cable Connection with Fast-Mate ConnectionInput Cable LN-10 Control to Power Source Electrical InstallationGmaw Shielding Gas Optional Features Installation Dual Procedure Switch OptionsSetup DIP Switch Access LN-10 Control DIP Switch SetupOperation Wire Drive Head Selection Setting the DIP SwitchesWelding Power Source Selection Metric/English Wire Feed Speed Display Selection Step Trigger Mode Operation SelectionMaximum Limits Setting Mode Selection Security Mode SelectionRobotics Mode Selection Minimum Limits Setting Mode SelectionKeypad and Display Description Power-Down SaveKeypad and Display Operation Operation KeysTrigger Mode Select Key Trigger Mode SelectionDisplay Control Keys Acceleration Selection Security ModeControl Select key enables operator to Digital Memory VoltmeterMaximum and Minimum Limits Setting Modes Dual Procedure Remote Control K1449-1 Wire Reel Loading READI-REELS, Spools or CoilsFeeding Electrode and Brake Adjustment Drive Roll Pressure SettingGAS Guard Regulator Setting Procedure for Setting Angle of FeedplateMaking a Weld Wire Feed Overload Protection Wire Reel ChangingGrounding Lead Protector Explanation of Prompting and Error Messages Display Prompt or ErrorAccessories K683-1 Dual Procedure Switch K683-3 Dual Procedure SwitchK1449-1 Dual Procedure Remote Control GUN Adapters for 10 Series Wire DriveGUN and Cable Assemblies K1557-1 Swivel Mount K1558-1 Remote Switch Interface ModuleK1634-3 Wire Reel Enclosure KIT K1556-1 Light Duty Caster KITGun and Cable Maintenance MaintenanceWire Drive Motor and Gearbox Drive Rolls and Guide TubesTroubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnProblems Symptoms Recommended Course of Action Contact your local Lincoln Authorized Field Service Facility Troubleshooting Problems Possible Recommended Troubleshooting Voltage DIP switch S1 is incorrectly set for Procedure for Replacing PC Boards Electric Shock can killDiagrams 10-STT/ Wire DRI VE Dimension Print 18903LN-10 LN-10 Precaucion Warnung