Lincoln Electric LN-10 Input Cable Assemblies, K683-3 Dual Procedure Switch, Spindle Adapters

Page 28

C-2

ACCESSORIES

C-2

 

 

 

INPUT CABLE ASSEMBLIES:

K1797-25

Consists of a 14-conductor control cable extension 25ʼ in length.

K683-3 DUAL PROCEDURE SWITCH

Kit includes gun switch, and mountings for Lincoln Innershield and Magnum guns, with 15 ft. (4.5m) con- trol cable and 5-pin plug with two leads to connect to gun trigger.

K1797-50

Consists of a 14-conductor control cable extension 50ʼ in length.

Note: Extensions can only be connected up to 100ʼ Maximum length.

K1520-2 115V/42V TRANSFORMER KIT

Required to use LN-10 with Lincoln Power Sources without 42VAC auxiliary and a 14-pin connector recep- tacle. These power sources include the DC-250, DC-

600(Below Code 10500), DC-1000 and Pulse Power

500.Also can be used with older DC-400 models.

K590-4 WATER CONNECTION KIT

Includes water cooled gun tube fittings and self-sealing outlet and inlet quick-connectors for mounting into the DH wire drive connection box.

K659-1 GAS GUARD REGULATOR

Adjustable flow regulator with removable adjustor key for CO2 and Argon blend gases. Mounts onto wire drive gas inlet, and reduces gas waste and arc start "blow" by reducing surge caused by excess pressure in supply hose.

SPINDLE ADAPTERS:

Coil Adapter:

K1504-1Permits 50 lb to 60 lb (22.7-27.2 Kg.) Coils to be mounted on 2” (51 mm) O.D. spindles.

K435 Permits 14 lb. (6 kg) Innershield coils to be mounted on 2" (51 mm) O.D. spindles.

K468 Permits 8" (203 mm) O.D. spools to be mount- ed on 2" (51 mm) O.D. spindles.

Readi-Reel Adapters:

K363P Adapts Lincoln Readi-Reel coils of electrode 30 lb. (14 kg) and 22 lb. (10 kg) to a 2" (51 mm) spin- dle. Durable molded plastic one piece construction. Designed for easy loading; adapter remains on spin- dle for quick changeover.

K438 Adapts Lincoln Readi-Reel coils of electrode 50-60 lb. (22.7-27.2 kg) to a 2" (51 mm) spindle.

K1449-1 DUAL PROCEDURE REMOTE CONTROL

Includes a remote control box with a 16 ft. (5 m) length control cable with 4-pin plug for the mating receptacle on the bottom of the LN-10 control box. The remote con- trol box contains a procedure selector switch and 2 rotating knob encoders, one controls arc voltage and the other controls wire feed speed, which function the same as comparable controls on the LN-10 front panel, when the remote is connected and selected by the LN-10 Procedure Key.

K1450-”L”- Extension cables are available in lengths “L” of 12, 16 or 25 ft. (3.6, 4.9 or 7.6) to match the con- trol to Feeder cable length used.

K683-1 DUAL PROCEDURE SWITCH

Requires K686-2 Adapter for LN-10. Kit includes gun switch, and mountings for Lincoln Innershield and Magnum guns, with 15 ft. (4.5 m) control cable and 3- pin plug. K686-2 Adapter permits 3-pin plug and 5-pin gun trigger plug to be connected to LN-10 5-pin Trigger/Dual Procedure receptacle.

GUN ADAPTERS (FOR 10 SERIES WIRE DRIVE)

The LN-10 wire feeder is equipped with a factory installed K1500-2 gun connection kit. This kit is for guns having a Tweco #2-#4 type connector. The LN- 10 has been designed to make connecting a variety of guns easy and inexpensive with the K1500 series of gun connection kits. Gun trigger and dual procedure lead connections connect to the single 5 pin recepta- cle on the front of the feed head box.

Magnum 200/300/400 Guns

The easiest and least expensive way to use Magnum 200/300/400 guns with the LN-10 wire feeder is to order them with the K466-2 connector kit, or to buy a completely assembled Magnum gun having the K466-

2connector (such as the K497-21,-22,-23 dedicated Magnum 400 guns and the K497-20,-21 dedicated Magnum 200 guns).

LN-10

Image 28
Contents IM906 Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation General DescriptionRecommended Processes and Equipment Available ModelsWire Drive Speed Range Selection Control Speed Range SettingSeries Wire Drive Ratio Selection Electrode RoutingProcedure to Install Drive Roll and Wire Guides Wire Feed Drive Roll KitsGUN and Cable Assemblies with Standard Connection Series Wire Drive Water Connections for Water Cooled Guns GUN and Cable Assemblies with FAST-MATE ConnectionGun Cable Connection with Standard Connection Gun Cable Connection with Fast-Mate ConnectionInput Cable LN-10 Control to Power Source Electrical InstallationGmaw Shielding Gas Optional Features Installation Dual Procedure Switch OptionsSetup DIP Switch Access LN-10 Control DIP Switch SetupOperation Wire Drive Head Selection Setting the DIP SwitchesWelding Power Source Selection Metric/English Wire Feed Speed Display Selection Step Trigger Mode Operation SelectionSecurity Mode Selection Robotics Mode SelectionMaximum Limits Setting Mode Selection Minimum Limits Setting Mode SelectionPower-Down Save Keypad and Display OperationKeypad and Display Description Operation KeysTrigger Mode Select Key Trigger Mode SelectionDisplay Control Keys Security Mode Control Select key enables operator toAcceleration Selection Digital Memory VoltmeterMaximum and Minimum Limits Setting Modes Dual Procedure Remote Control K1449-1 Wire Reel Loading READI-REELS, Spools or CoilsFeeding Electrode and Brake Adjustment Drive Roll Pressure SettingGAS Guard Regulator Setting Procedure for Setting Angle of FeedplateMaking a Weld Wire Feed Overload Protection Wire Reel ChangingGrounding Lead Protector Explanation of Prompting and Error Messages Display Prompt or ErrorAccessories K683-3 Dual Procedure Switch K1449-1 Dual Procedure Remote ControlK683-1 Dual Procedure Switch GUN Adapters for 10 Series Wire DriveGUN and Cable Assemblies K1558-1 Remote Switch Interface Module K1634-3 Wire Reel Enclosure KITK1557-1 Swivel Mount K1556-1 Light Duty Caster KITMaintenance Wire Drive Motor and GearboxGun and Cable Maintenance Drive Rolls and Guide TubesTroubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnProblems Symptoms Recommended Course of Action Contact your local Lincoln Authorized Field Service Facility Troubleshooting Problems Possible Recommended Troubleshooting Voltage DIP switch S1 is incorrectly set for Procedure for Replacing PC Boards Electric Shock can killDiagrams 10-STT/ Wire DRI VE Dimension Print 18903LN-10 LN-10 Precaucion Warnung