Lincoln Electric LN-10 manual K1557-1 Swivel Mount, K1556-1 Light Duty Caster KIT

Page 30

C-4

ACCESSORIES

C-4

 

 

 

K478 Magnum 300 FM GMAW gun and cable assemblies are rated for 300 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

K479 Magnum 400 FM GMAW gun and cable assemblies are rated for 400 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

USING DUAL PROCEDURE WITH FAST-MATE GUNS

There are a number of different options available for using dual procedure with Fast-Mate guns. These configurations are outlined below along with any addi- tional required equipment.

K1557-1 SWIVEL MOUNT

The K1557-1 Swivel mount attaches to the power source. This kit includes a feeder adapter plate that allows the feeder to rotate on top of the power source. The feeder can be easily separated from the swivel mount at any time. This option is compatible with the K1556-1 Light Duty Caster Kit.

K1556-1 LIGHT DUTY CASTER KIT

This option provides 4 casters and all required hard- ware to mount it to the Power Feed 10. This option is compatible with the K1557-1 Swivel Mount.

Using Dual Schedule with Fast-Mate Guns on -10 Series Feeders

Configuration 1

K489-9Dual Schedule Fast-Mate adapter

K575-Magnum 400 DS/FM gun (or competitive DS/FM gun)

Configuration 2

K489-9Dual Schedule Fast-Mate adapter

K683-1Dual Procedure Switch (3 pin)

K686-2"Y" adapter (3pin + 5 pin to 5 pin)

K* Non-DS Fast-Mate gun (Magnum 450WC, Magnum 200, Magnum 300, Magnum 400, and others)

K1558-1 REMOTE SWITCH INTERFACE MODULE

The Module provides for user interface connection of an external switch (flow switch, etc.) which must be closed to enable the feeder welding operation. Also, the Module provides for interface connection of exter- nal equipment (fume extractor, etc.) to the Moduleʼs isolated relay contacts which actuate when the feeder welding gas solenoid is activated (representing weld- ing operation in process).

K1561-1 ROBOTICS INTERFACE MODULE

The module plugs directly into the LN-10 control board and provides an interface to a properly equipped Fanuc robot. When installed and properly configured, the K1561-1 Robotics Interface Module allows com- plete control of the welding process from the robot controller.

The Lincoln Electric Companyʼs Automation Center should be contacted for questions regarding installa- tion or operation of the Robotics Interface Module.

K1555-1 INSULATED LIFT HOOK

For applications where an insulated lift hook is required. This kit provides an easily installed, heavy duty insulated lift eye that mounts to the wire reel stand mast. See the instructions provided with the kit for installation.

K1634-3 WIRE REEL ENCLOSURE KIT

The K1634-3 Wire Reel Enclosure Kit provides the necessary parts to cover the wire and protect it from excessive dirt and contamination. The kit is not for use with 60lb coils (most 30 lb, 15kg, 44 lb fiber spools, and smaller coils will work). The kit includes a 2 part plastic reel cover, a Magnum conduit adapter for the incoming end of the wire feeder feed plate, and a short length of Magnum conduit to go between the reel cover and the feedplate.

LN-10

Image 30
Contents IM906 Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Recommended Processes and Equipment InstallationGeneral Description Available ModelsSeries Wire Drive Ratio Selection Wire Drive Speed Range SelectionControl Speed Range Setting Electrode RoutingWire Feed Drive Roll Kits Procedure to Install Drive Roll and Wire GuidesGUN and Cable Assemblies with Standard Connection Gun Cable Connection with Standard Connection Series Wire Drive Water Connections for Water Cooled GunsGUN and Cable Assemblies with FAST-MATE Connection Gun Cable Connection with Fast-Mate ConnectionElectrical Installation Input Cable LN-10 Control to Power SourceGmaw Shielding Gas Optional Features Installation Dual Procedure Switch OptionsLN-10 Control DIP Switch Setup Setup DIP Switch AccessOperation Setting the DIP Switches Wire Drive Head SelectionWelding Power Source Selection Metric/English Wire Feed Speed Display Selection Step Trigger Mode Operation SelectionMaximum Limits Setting Mode Selection Security Mode SelectionRobotics Mode Selection Minimum Limits Setting Mode SelectionKeypad and Display Description Power-Down SaveKeypad and Display Operation Operation KeysTrigger Mode Selection Trigger Mode Select KeyDisplay Control Keys Acceleration Selection Security ModeControl Select key enables operator to Digital Memory VoltmeterMaximum and Minimum Limits Setting Modes Dual Procedure Remote Control K1449-1 Wire Reel Loading READI-REELS, Spools or CoilsFeeding Electrode and Brake Adjustment Drive Roll Pressure SettingProcedure for Setting Angle of Feedplate GAS Guard Regulator SettingMaking a Weld Wire Reel Changing Wire Feed Overload ProtectionGrounding Lead Protector Explanation of Prompting and Error Messages Display Prompt or Error Accessories K683-1 Dual Procedure Switch K683-3 Dual Procedure SwitchK1449-1 Dual Procedure Remote Control GUN Adapters for 10 Series Wire DriveGUN and Cable Assemblies K1557-1 Swivel Mount K1558-1 Remote Switch Interface ModuleK1634-3 Wire Reel Enclosure KIT K1556-1 Light Duty Caster KITGun and Cable Maintenance MaintenanceWire Drive Motor and Gearbox Drive Rolls and Guide TubesTroubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnProblems Symptoms Recommended Course of Action Contact your local Lincoln Authorized Field Service Facility Troubleshooting Problems Possible Recommended Troubleshooting Voltage DIP switch S1 is incorrectly set for Procedure for Replacing PC Boards Electric Shock can killDiagrams 10-STT/ Wire DRI VE Dimension Print 18903LN-10 LN-10 Precaucion Warnung