TROUBLESHOOTING | ||
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Pressing the procedure key does | 1. | The connector from the control |
|
not select between A - Remote - B. |
| p.c. board to the display p.c. |
|
|
| board or the connector from the |
|
|
| display p.c. board to the keypad |
|
|
| are loose or improperly inserted. |
|
| 2. | Damaged keypad |
|
| 3. | Damaged display p.c. board. |
|
| 4. | Damaged control p.c. board. |
|
|
|
|
|
Pressing the timer or control key has | 1. | Make sure that the DIP switches |
|
no effect while not welding. |
| on the control p.c. board are not |
|
|
| set for security mode. |
|
| 2. | The connector from the control |
|
|
| p.c. board to the display p.c. |
|
|
| board or the connector from the |
|
|
| display p.c. board to the keypad |
|
|
| are loose or improperly inserted. |
|
| 3. | Damaged keypad | If all recommended possible areas |
|
|
| of misadjustment have been |
| 4. | Damaged display p.c. board. | checked and the problem persists, |
|
|
| Contact your local Lincoln |
| 5. | Damaged control p.c. board. | Authorized Field Service Facility. |
|
|
|
|
Pressing the trigger key has no | 1. | The connector from the control |
|
effect while not welding. |
| p.c. board to the display p.c. |
|
|
| board or the connector from the |
|
|
| display p.c. board to the keypad |
|
|
| are loose or improperly inserted. |
|
| 2. | Damaged keypad |
|
| 3. | Damaged display p.c. board. |
|
| 4. | Damaged control p.c. board. |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.