Lincoln Electric LN-10 manual GUN and Cable Assemblies

Page 29

C-3

ACCESSORIES

C-3

 

 

 

Magnum 550 Guns

The easiest and least expensive way to use the Magnum 550 guns with LN-10 wire feeders is to order the gun with the K613-2 connector kit, and install a K1500-3 gun connection kit to the wire feeder.

Lincoln Innershield and Sub Arc Guns

All of these guns can be connected to the LN-10 by using the K1500-1 Adapter Kit.

Lincoln Fume Extraction Guns

The K556 (250XA) and K566 (400XA) guns require that a K489-9 Fast-Mate adapter kit be installed.

The K206, K289, and K309

require only the installation of a K1500-1 connector in the LN-10 wire feeder.

Non-Lincoln Guns

Most competitive guns can be connected to the LN-10 by using one of the K1500 series adapter kits.

K1500-1(Lincoln Innershield gun standard connection) Use this kit to connect the following guns: Guns having a Lincoln standard innershield gun connector, Magnum 200/300/400 with K466-1 connector kit, and Magnum 550 guns with the K613-1 gun connection kit.

K1500-2(Tweco #2-#4 type connection)

The K1500-2 gun adapter comes factory installed on the LN-10 wire feeder. Use this adapter for guns that have a Tweco #2-#4 connector. Such guns include Magnum 200/300/400 guns with K466-2 connector kit, and complete- ly factory assembled Magnum guns that are factory equipped with the K466-2 connector (such as the K471-21, - 22, and -23 dedicated Magnum 400 guns and the K497-20 and -21 Magnum 200 guns).

K1500-3(Tweco #5 connection)

For Magnum 550 gun with K613-2 Connection Kit, and any other gun having a Tweco #5 connector .

K1500-4(Miller connection)

For any gun having a newer style Miller connector.

GUN RECEIVER BUSHINGS AND GUN ADAPTERS

K489-9 (Dual Schedule Fast-Mate Adapter)

This adapter installs directly into the wire drive feed- plate, to provide for use of guns with Fast-Mate or European style gun connections. This K489-9 will handle both standard Fast-Mate and Dual Schedule Fast-Mate guns.

GUN AND CABLE ASSEMBLIES

The following Lincoln gun and cable assemblies are compatible with 10 Series Wire Feed heads with appropriate K1500 Gun Adapter:

K126 (Requires K1500-1) Innershield gun and cable assemblies are rated at 350 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

K115 (Requires K1500-1) Innershield gun and cable assemblies are rated at 450 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

K470 (With K466-9 requires K1500-2) Magnum 300 GMAW gun and cable assemblies are rated 300 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

K471 (With K466-9 requires K1500-2) Magnum 400 GMAW gun and cable assemblies are rated 400 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

K497 (With K466-9 requires K1500-2) Magnum 200 GMAW gun and cable assemblies are rated 200 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

K541 (With K466-9 requires K1500-2) Magnum 400 Short Neck GMAW gun and cable assemblies are rated 400 amps, 60% duty cycle. (Consult sales specifications for appropriate models)

K598 (With K613-7 requires K1500-3) Magnum 550 GMAW gun and cable assemblies are rated 550 amps, 60% duty cycle. (Consult sales specifications for appropriate models) The following Lincoln gun and cable assemblies are equipped with a Fast-Mate™ connector. They can be used with 10 Series wire feed models by installing a K489-10 Fast-Mate™ adapter kit and a K1500-1 Lincoln Gun adapter.

K684 Magnum "Super Cool" FM water cooled GMAW gun and cable assemblies are rated 450 amps, 100% duty cycle (CO2). (Consult sales specifi- cations for appropriate models)

K498 Magnum 200 FM GMAW gun and cable assemblies are rated for 200 amps 60% duty cycle. (Consult sales specifications for appropriate models)

K534 Magnum 250L FM GMAW gun and cable assemblies are rated for 250 amps, 30% duty cycle. (Consult sales specifications for appropriate models)

LN-10

Image 29
Contents IM906 California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents General Description InstallationRecommended Processes and Equipment Available ModelsControl Speed Range Setting Wire Drive Speed Range SelectionSeries Wire Drive Ratio Selection Electrode RoutingGUN and Cable Assemblies with Standard Connection Wire Feed Drive Roll KitsProcedure to Install Drive Roll and Wire Guides GUN and Cable Assemblies with FAST-MATE Connection Series Wire Drive Water Connections for Water Cooled GunsGun Cable Connection with Standard Connection Gun Cable Connection with Fast-Mate ConnectionGmaw Shielding Gas Electrical InstallationInput Cable LN-10 Control to Power Source Dual Procedure Switch Options Optional Features InstallationOperation LN-10 Control DIP Switch SetupSetup DIP Switch Access Welding Power Source Selection Setting the DIP SwitchesWire Drive Head Selection Step Trigger Mode Operation Selection Metric/English Wire Feed Speed Display SelectionRobotics Mode Selection Security Mode SelectionMaximum Limits Setting Mode Selection Minimum Limits Setting Mode SelectionKeypad and Display Operation Power-Down SaveKeypad and Display Description Operation KeysDisplay Control Keys Trigger Mode SelectionTrigger Mode Select Key Control Select key enables operator to Security ModeAcceleration Selection Digital Memory VoltmeterMaximum and Minimum Limits Setting Modes Wire Reel Loading READI-REELS, Spools or Coils Dual Procedure Remote Control K1449-1Drive Roll Pressure Setting Feeding Electrode and Brake AdjustmentMaking a Weld Procedure for Setting Angle of FeedplateGAS Guard Regulator Setting Grounding Lead Protector Wire Reel ChangingWire Feed Overload Protection Display Prompt or Error Explanation of Prompting and Error MessagesAccessories K1449-1 Dual Procedure Remote Control K683-3 Dual Procedure SwitchK683-1 Dual Procedure Switch GUN Adapters for 10 Series Wire DriveGUN and Cable Assemblies K1634-3 Wire Reel Enclosure KIT K1558-1 Remote Switch Interface ModuleK1557-1 Swivel Mount K1556-1 Light Duty Caster KITWire Drive Motor and Gearbox MaintenanceGun and Cable Maintenance Drive Rolls and Guide TubesHOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service FacilityProblems Symptoms Recommended Course of Action Contact your local Lincoln Authorized Field Service Facility Troubleshooting Problems Possible Recommended Troubleshooting Voltage DIP switch S1 is incorrectly set for Electric Shock can kill Procedure for Replacing PC BoardsDiagrams 10-STT/ Wire DRI VE 18903 Dimension PrintLN-10 LN-10 Precaucion Warnung