Lincoln Electric LN-10 Wire Feed Drive Roll Kits, Procedure to Install Drive Roll and Wire Guides

Page 10

A-3

INSTALLATION

A-3

 

 

 

WIRE FEED DRIVE ROLL KITS

NOTE: The maximum rated solid and cored wire sizes for each wire drive head and selected drive ratio is shown on the SPECIFICATIONS in the front of this section.

The electrode sizes that can be fed with each roll and guide tube are stenciled on each part. Check the kit for proper components.

10 Series Wire Drives use 4-Roll drive roll kits with 4 driven rolls, per Table C.1 in ACCESSORIES.

PROCEDURE TO INSTALL DRIVE ROLL AND WIRE GUIDES

WARNING

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such

as output terminals or internal wiring.

When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

------------------------------------------------------------------------

10 Series Wire Drive Roll Kit Installation (KP1505 and KP1507)

1)Turn OFF Welding Power Source.

2)Pull open Pressure Door to expose rolls and wire guides.

3)Remove Outer Wire Guide by turning knurled thumb screws to unscrew from Feedplate.

4)Remove drive rolls, if any are installed, by pulling straight off shaft. Remove inner guide.

5)Insert inner Wire Guide, groove side out, over the two locating pins in the feedplate.

6)Install each drive roll by pushing over shaft until it butts up against locating shoulder on the drive roll shaft. (Do Not exceed maximum wire size rating of the wire drive).

7)Install Outer Wire Guide by sliding over locating pins and tightening in place.

8)Engage upper drive rolls if they are in the “open” position and close Pressure Door.

TO SET IDLE ROLL PRESSURE, see “Idle Roll Pressure Setting” in OPERATION.

GUN AND CABLE ASSEMBLIES WITH STANDARD CONNECTION

The 10 Series Wire Drive Heads each require a K1500 Gun Adapter installed See “Gun Adapters” in ACCESSORIES section. The K1500-2 Gun Adapter and Trigger Cable for Magnum 200-400 guns are fac- tory included with the LN-10.

GMAW Guns

An expanding line of Magnum gun and cable assem- blies are available to allow welding with solid and cored electrodes using the GMAW process See the appropriate Magnum literature for descriptions of the 200 to 550 ampere air cooled gun and cables that are available. Gun cable lengths range from 10 ft. (3.0 m) to 25 ft. (7.6 m) and feed electrode sizes .025" (0.6

mm)to 3/32" (2.4 mm). The entire line of Magnum Fast-Mate gun and cable assemblies can also be used by installing a K489-10 Fast-Mate adapter kit. See “Gun and Cable Assemblies with Fast-Mate Connection” in this section for details.

Innershield Guns

K126 and K115 gun and cable assemblies are avail- able to allow welding with Innershield electrodes. Gun cable lengths range from 10 ft. (3.0 m) to 15 ft. (4.5 m) The 350 ampere K126 will feed electrode sizes .062 (1.6 mm) to 3/32" (2.4 mm). The 450 ampere K115 will feed 5/64" (2.0 mm) to 3/32" (2.4 mm) electrode.

Three smoke extraction gun and cable assemblies are available, 250 ampere K309, 350 ampere K206 and the 500 ampere K289. All gun cable lengths are 15 ft. (4.5 m). These guns will feed electrode sizes .062" (1.6 mm) to 3/32" (2.4 mm) and require the use of the K184 vacuum unit for use with the LN-10.

LN-10

Image 10
Contents IM906 Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Recommended Processes and Equipment InstallationGeneral Description Available ModelsSeries Wire Drive Ratio Selection Wire Drive Speed Range SelectionControl Speed Range Setting Electrode RoutingProcedure to Install Drive Roll and Wire Guides Wire Feed Drive Roll KitsGUN and Cable Assemblies with Standard Connection Gun Cable Connection with Standard Connection Series Wire Drive Water Connections for Water Cooled GunsGUN and Cable Assemblies with FAST-MATE Connection Gun Cable Connection with Fast-Mate ConnectionInput Cable LN-10 Control to Power Source Electrical InstallationGmaw Shielding Gas Optional Features Installation Dual Procedure Switch OptionsSetup DIP Switch Access LN-10 Control DIP Switch SetupOperation Wire Drive Head Selection Setting the DIP SwitchesWelding Power Source Selection Metric/English Wire Feed Speed Display Selection Step Trigger Mode Operation SelectionMaximum Limits Setting Mode Selection Security Mode SelectionRobotics Mode Selection Minimum Limits Setting Mode SelectionKeypad and Display Description Power-Down SaveKeypad and Display Operation Operation KeysTrigger Mode Select Key Trigger Mode SelectionDisplay Control Keys Acceleration Selection Security ModeControl Select key enables operator to Digital Memory VoltmeterMaximum and Minimum Limits Setting Modes Dual Procedure Remote Control K1449-1 Wire Reel Loading READI-REELS, Spools or CoilsFeeding Electrode and Brake Adjustment Drive Roll Pressure SettingGAS Guard Regulator Setting Procedure for Setting Angle of FeedplateMaking a Weld Wire Feed Overload Protection Wire Reel ChangingGrounding Lead Protector Explanation of Prompting and Error Messages Display Prompt or ErrorAccessories K683-1 Dual Procedure Switch K683-3 Dual Procedure SwitchK1449-1 Dual Procedure Remote Control GUN Adapters for 10 Series Wire DriveGUN and Cable Assemblies K1557-1 Swivel Mount K1558-1 Remote Switch Interface ModuleK1634-3 Wire Reel Enclosure KIT K1556-1 Light Duty Caster KITGun and Cable Maintenance MaintenanceWire Drive Motor and Gearbox Drive Rolls and Guide TubesTroubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnProblems Symptoms Recommended Course of Action Contact your local Lincoln Authorized Field Service Facility Troubleshooting Problems Possible Recommended Troubleshooting Voltage DIP switch S1 is incorrectly set for Procedure for Replacing PC Boards Electric Shock can killDiagrams 10-STT/ Wire DRI VE Dimension Print 18903LN-10 LN-10 Precaucion Warnung