A-5

INSTALLATION

A-5

 

 

 

INSTALLATION OF THE SYNERGIC 7F COMPONENTS

Safety Precautions

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

Mounting the Wire Feed Unit (K679-1 or -2)

Mount the wire feed unit by means of the insulated mounting bracket attached to the bottom of the gear- box. Reference L9777 dimension print at the rear of this manual to find the size and location of the mount- ing holes. The gearbox assembly is electrically “hot” when the gun trigger is pressed. Therefore, make cer- tain the gearbox does not come in contact with the structure on which the unit is mounted.

The wire feed unit should be mounted so that the drive rolls are in a vertical plane so dirt will not collect in the drive roll area. Position the mechanism so it will point down at about a 45° angle so the wire feed gun cable will not be bent sharply as it comes from the unit.

Mounting the Control Box (K678-2)

The same control box is used for both the Synergic 7F and Synergic 7FH wire feed units and contains two keyhole slots and one slot for mounting. Reference M17740 dimension print in the rear of this manual for size and location of these slots. Mount the box at some convenient location close to the wire feed unit which will enable the desired control cable assembly to reach between the control box and the wire feed unit.

a)Drill the required holes in the mounting surface, partially install 1/4-20 screws.

b)Open the control box door by removing the two

door screws.

c)Mount the box.

d)Tighten the screws.

e)Close the control box door and replace the door screws.

Connecting Wire Feed Unit to Control Box

The Feeder to Control cable assemblies are available in two types:

K680-”L” Includes a control cable with 14-pin MS- style connectors on each end, and a 4/0 weld cable to route between the Wire Drive and the Control Box. Available in lengths “L” of 16ft. (4.9m) and 25ft. (7.6m).

K681-”L” Same as K680, but does not include weld cable. Available in lengths “L” of 12ft. (3.6m), 16ft. (4.9m) and 25ft. (7.6m).

1.Making certain the cables are protected from any sharp corners which may damage their jackets, mount the cable assembly along the boom so the end with the female MS-style connector pins is at the wire feed unit.

2.Connect the 14-socket cable connector to the receptacle on the back of the wire feed unit con- nection box.

3.At the same end, connect the electrode lead to the connection stud of the brass gun connection block on the front of the wire feed unit.

4.At the control box end, connect the 14-pin connec- tor of the cable to the mating receptacle on the bottom of the control box.

Electrode Routing

The electrode supply may be either from reels, Readi- Reels, spools or bulk packaged drums or reels. Observe the following precautions:

1.The electrode must be routed to the wire feed unit so that the bends in the wire are at a minimum, and also that the force required to pull the wire from the reel into the wire feed unit is kept at a minimum.

2.The electrode is “hot” when the gun is energized and must be insulated from the boom and struc- ture.

3.If more than one wire feed unit shares the same boom, their wire and reels must be insulated from each other and insulated from their mounting structure.

SYNERGIC 7F & FH

Image 12
Contents Synergic 7F and Synergic 7FH Safety Mar ‘95Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Mar. ‘93Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation Type K678-2 K679-1 K679-2 Wire Speed RangeModel Standard Features Wire Feed FeaturesGeneral Description Recommended Processes and EquipmentControl Features Y P a D a N D D I S P L a Y Description Safety Precautions Connecting Wire Feed Unit to Control BoxElectric Shock can kill Mounting the Control Box K678-2Procedure to Install Drive Roll and Guide Tubes Wire Feed Drive Roll and Guide Tube KitsSteel Wire Sizes Roll Aluminum Wire SizesGun and Cable Assemblies with Standard L. E. Connections Gun Cable ConnectionGmaw Guns Innershield GunsGun Cable Connections Wire Feeder to Gun Synergic 7F Water Connections for Water-Cooled GunsGmaw Shielding Gas Cylinder may explode if damagedElectrical Installation Work CableCurrent 60% Duty Cycle Up to 100 ft Length 30mOptional Features Installation K648, K649 or K642 Input Cable Assembly SeeElectrical Installation section for instructions Power-Down Save Mode SelectionOperation Operating InstructionsDisplay Control Keys Timer/Crater Select key enables Procedure Selector Switch Memory Ammeter Selection4-step with crater fill Feeding Electrode and Brake Adjustment To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm DiameterTo Mount a 50-60lb 22.7-27.2kg Coil Feeding ElectrodeWire Loading of 13-14lb 6kg Innershield Coils Idle Roll Pressure SettingGas Guard Regulator Setting Wire Reel Changing Wire Feed Overload ProtectionMaking a Weld Explanation of Prompting Error Messages Accessories Optional FeaturesREADI-REEL Adapters Maintenance MaintenanceTroubleshooting Troubleshooting GuideTrouble shooting information Replace contact tipTions in control cable Welding Ing and gas flow rate is properIng ReplaceNo control of wire feed Ters on wire feeder display do notDefective wire feed motor tach or Control PC board see Procedure forWire feed motor runs and solenoid Power source is defective Wiring harness or Control PCSpeed does not change when Run-in and weld speeds are set Or there may be a problem withMeters on wire feeder display do Not match those on powerProblem with wire feeder harness Remote control kit must be usedTroubleshooting Dure switch Be connected Between procedures a and BDisplay. If not, refer to Problem Faulty local dual procedure switchLocal dual procedure switch Dual procedure switch is used toSwitch between procedures a Faulty communication betweenBreaker at power source is blown Or trippedCircuit breaker Display or Control PC board is BadSee Problem 5 or see Section on Cedure for replacing PC boards Eprom checksum errorOnds. Turn power back on. If EP is X8 on Control PC board is faultyProcedure for Replacing PC Boards Electric Shock can kill Switch RequirementsDIAGRAMSF-1 Control P.C BoardDiagrams Input Connection DiagramPrint Wire Feed Unit Dimension Print Synergic 7F & FH Synergic 7F & FH Precaucion Warnung