Lincoln Electric IM559 manual To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter

Page 22
(Requires installation

B-5

OPERATION

B-5

 

 

 

MOLDED ADAPTER

2" O.D. SPINDLE

RETAINING SPRING

Brake Holding Pin (Must engage hole in adapter rib)

PIN

GROOVES

Installation of K363-P Readi-Reel Adapter

READI-REEL

INSIDE CAGE WIRES

THREADED LOCKING COLLAR

Wire Reel Loading - Readi-Reels and Spools (Using K162H Spindle Kit with 2” (51mm) spindle)

TO MOUNT A 30 LB (14 kg) READI-REEL PACKAGE USING THE MOLDED PLASTIC K363-P TYPE ADAPTER:

1)Make certain that the threaded locking collar is tight and securely locks the adapter on the spindle (see figure above).

2)Rotate the spindle and adapter so the retaining spring is at the 12 o’clock position.

3)Position the Readi-Reel so that it will rotate in a clockwise direction when feeding (wire is to be de- reeled from bottom of the coil).

4)Set one of the Readi-Reel inside cage wires on the slot in the retaining spring tab.

5)Lower the Readi-Reel to depress the retaining spring and align the other inside cage wires with the grooves in the molded adapter.

6)Slide cage all the way onto the adapter until the retaining spring “pops up” fully.

WARNING

Check to be sure the Retaining Spring has fully returned to the locking position and has SECURELY locked the Readi-Reel Cage in place. Retaining Spring must rest on the cage, not the welding elec- trode.

___________________________________________

7)To remove Readi-Reel from Adapter, depress retaining spring tab with thumb while pulling the Readi-Reel cage from the molded adapter with both hands. Do not remove adapter from the spindle.

To Mount 10 to 44 lb (4.5-20kg) Spool (12”/300mm Diameter):

of 2” (51mm) spindle K162H Kit. For 8” (200mm) spools, a K468 spindle adapter must be used.)

1)Remove the locking collar on the 2” (51mm) diam- eter spindle.

2)Place the spool on the spindle making certain the brake holding pin enters one of the holes in the back side of the spool. Be certain the wire comes off the reel in a clockwise direction when de-reeled from the bottom of the coil.

3)Replace and tighten the locking collar.

Feeding Electrode and Brake Adjustment

1)Turn the Readi-Reel or spool until the free end of the electrode is accessible.

2)While tightly holding the electrode, cut off the bent end and straighten the first 6” (150mm). Cut off the first 1” (25mm). (If the electrode is not properly straightened, it may not feed or may not go into the outgoing guide tube causing a “birdnest”.)

3)Insert the free end through the incoming guide tube.

4)Press the Cold Inch key or the gun trigger and push the electrode into the drive roll.

WARNING

When feeding with the gun trigger, the electrode and drive mechanism are always “HOT” to work and ground and could remain “HOT” several seconds after the gun trigger is released.

___________________________________________

5)Feed the electrode through the gun.

6)Adjust the brake tension with the thumbscrew on the spindle hub, until the reel turns freely but with little or no overrun when wire feeding is stopped. Do not overtighten.

SYNERGIC 7F & FH

Image 22
Contents Synergic 7F and Synergic 7FH Safety Mar ‘95Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Mar. ‘93Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Type K678-2 K679-1 K679-2 Wire Speed Range InstallationModel General Description Standard FeaturesWire Feed Features Recommended Processes and EquipmentControl Features Y P a D a N D D I S P L a Y Description Electric Shock can kill Safety PrecautionsConnecting Wire Feed Unit to Control Box Mounting the Control Box K678-2Steel Wire Sizes Roll Procedure to Install Drive Roll and Guide TubesWire Feed Drive Roll and Guide Tube Kits Aluminum Wire SizesGmaw Guns Gun and Cable Assemblies with Standard L. E. ConnectionsGun Cable Connection Innershield GunsGmaw Shielding Gas Gun Cable Connections Wire Feeder to GunSynergic 7F Water Connections for Water-Cooled Guns Cylinder may explode if damagedCurrent Electrical InstallationWork Cable 60% Duty Cycle Up to 100 ft Length 30mK648, K649 or K642 Input Cable Assembly See Optional Features InstallationElectrical Installation section for instructions Operation Power-Down SaveMode Selection Operating InstructionsDisplay Control Keys Timer/Crater Select key enables Memory Ammeter Selection Procedure Selector Switch4-step with crater fill Feeding Electrode and Brake Adjustment To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm DiameterTo Mount a 50-60lb 22.7-27.2kg Coil Feeding ElectrodeIdle Roll Pressure Setting Wire Loading of 13-14lb 6kg Innershield CoilsGas Guard Regulator Setting Wire Feed Overload Protection Wire Reel ChangingMaking a Weld Explanation of Prompting Error Messages Accessories Optional FeaturesREADI-REEL Adapters Maintenance MaintenanceTroubleshooting Troubleshooting GuideReplace contact tip Trouble shooting informationTions in control cable Ing WeldingIng and gas flow rate is proper ReplaceDefective wire feed motor tach or No control of wire feedTers on wire feeder display do not Control PC board see Procedure forSpeed does not change when Run-in and weld speeds are set Wire feed motor runs and solenoid Power source is defectiveWiring harness or Control PC Or there may be a problem withProblem with wire feeder harness Meters on wire feeder display doNot match those on power Remote control kit must be usedTroubleshooting Display. If not, refer to Problem Dure switch Be connectedBetween procedures a and B Faulty local dual procedure switchSwitch between procedures a Local dual procedure switchDual procedure switch is used to Faulty communication betweenCircuit breaker Display or Control PC board is Breaker at power source is blownOr tripped BadOnds. Turn power back on. If EP is See Problem 5 or see Section onCedure for replacing PC boards Eprom checksum error X8 on Control PC board is faultyProcedure for Replacing PC Boards Electric Shock can kill Switch RequirementsDIAGRAMSF-1 Control P.C BoardDiagrams Input Connection DiagramPrint Wire Feed Unit Dimension Print Synergic 7F & FH Synergic 7F & FH Precaucion Warnung