Lincoln Electric IM559 manual Maintenance

Page 29

D-1

MAINTENANCE

D-1

 

 

 

MAINTENANCE

Safety Precautions

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

Routine Maintenance

Drive Rolls and Guide Tubes

After feeding every coil of wire, inspect the drive roll section. Clean it as necessary. Do not use a solvent for cleaning the idle roll because it may wash the lubricant out of the bearing. The driver roll and guide tubes are stamped with the wire sizes they will feed. If a wire size other than that stamped on the roll(s) is to be used, the roll(s) and guide tubes must be changed.

The drive rolls for .035” (0.9mm) through .052” (1.3mm) cored electrode and 1/16” (1.6mm) through 3/32” (2.4mm) electrode have a double set of teeth so they can be reversed for additional life. Drive rolls for

.023" (0.6 mm) through .052" (1.3 mm) solid elec- trodes and aluminum sizes have no teeth, but use two grooves so they also can be reversed for additional life.

See section on Wire Feed Drive Roll and Guide Tube Kits for roll changing instructions.

Wire Reel Mounting - 50 (22.7kg) and 60lb (27.2kg) Coils

To prolong the life of the reel shaft, periodically coat it with a thin layer of grease.

No maintenance of the two-position adjustable brake is needed. If the brake shoe wears through to the metal, replace the brake assembly.

Wire Reel Mounting - Readi-Reels and 10 through 30lb (4.5-14kg) Spools

No routine maintenance required. Do not lubricate 2” (51mm) spindle.

Avoiding Wire Feeding Problems

Wire feeding problems can be avoided by observing the following gun handling procedures:

a)Do not kink or pull cable around sharp corners.

b)Keep the electrode cable as straight as possible when welding or loading electrode through cable.

c)Do not allow dolly wheels or trucks to run over cables.

d)Keep cable clean by following maintenance instructions.

e)Use only clean, rust-free electrode. The Lincoln electrodes have proper surface lubrication.

f)Replace contact tip when the arc starts to become unstable or the contact tip end is fused or deformed.

g)Do not use excessive wire spindle brake settings.

Periodic Maintenance

Wire Drive Motor and Gearbox

Every year inspect the gearbox and coat the gear teeth with a moly-disulfide filled grease. Do not use graphite grease.

Every six months check the motor brushes. Replace them if they are less than 1/4” long.

Gun and Cable Maintenance

See appropriate Operator’s Manual.

SYNERGIC 7F & FH

Image 29
Contents Synergic 7F and Synergic 7FH Mar ‘95 SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionMar. ‘93 Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Model InstallationType K678-2 K679-1 K679-2 Wire Speed Range Wire Feed Features Standard FeaturesGeneral Description Recommended Processes and EquipmentControl Features Y P a D a N D D I S P L a Y Description Connecting Wire Feed Unit to Control Box Safety PrecautionsElectric Shock can kill Mounting the Control Box K678-2Wire Feed Drive Roll and Guide Tube Kits Procedure to Install Drive Roll and Guide TubesSteel Wire Sizes Roll Aluminum Wire SizesGun Cable Connection Gun and Cable Assemblies with Standard L. E. ConnectionsGmaw Guns Innershield GunsSynergic 7F Water Connections for Water-Cooled Guns Gun Cable Connections Wire Feeder to GunGmaw Shielding Gas Cylinder may explode if damagedWork Cable Electrical InstallationCurrent 60% Duty Cycle Up to 100 ft Length 30mElectrical Installation section for instructions Optional Features InstallationK648, K649 or K642 Input Cable Assembly See Mode Selection Power-Down SaveOperation Operating InstructionsDisplay Control Keys Timer/Crater Select key enables 4-step with crater fill Procedure Selector SwitchMemory Ammeter Selection To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter Feeding Electrode and Brake AdjustmentFeeding Electrode To Mount a 50-60lb 22.7-27.2kg CoilGas Guard Regulator Setting Wire Loading of 13-14lb 6kg Innershield CoilsIdle Roll Pressure Setting Making a Weld Wire Reel ChangingWire Feed Overload Protection Explanation of Prompting Error Messages Optional Features AccessoriesREADI-REEL Adapters Maintenance MaintenanceTroubleshooting Guide TroubleshootingTions in control cable Trouble shooting informationReplace contact tip Ing and gas flow rate is proper WeldingIng ReplaceTers on wire feeder display do not No control of wire feedDefective wire feed motor tach or Control PC board see Procedure forWiring harness or Control PC Wire feed motor runs and solenoid Power source is defectiveSpeed does not change when Run-in and weld speeds are set Or there may be a problem withNot match those on power Meters on wire feeder display doProblem with wire feeder harness Remote control kit must be usedTroubleshooting Between procedures a and B Dure switch Be connectedDisplay. If not, refer to Problem Faulty local dual procedure switchDual procedure switch is used to Local dual procedure switchSwitch between procedures a Faulty communication betweenOr tripped Breaker at power source is blownCircuit breaker Display or Control PC board is BadCedure for replacing PC boards Eprom checksum error See Problem 5 or see Section onOnds. Turn power back on. If EP is X8 on Control PC board is faultySwitch Requirements Procedure for Replacing PC Boards Electric Shock can killControl P.C Board DIAGRAMSF-1Input Connection Diagram DiagramsPrint Wire Feed Unit Dimension Print Synergic 7F & FH Synergic 7F & FH Precaucion Warnung