Lincoln Electric IM559 manual Electric Shock can kill

Page 3

ii

 

SAFETY

 

ii

 

 

 

 

 

 

 

 

 

ELECTRIC SHOCK can kill.

3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free

gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.

In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:

Semiautomatic DC Constant Voltage (Wire) Welder.

DC Manual (Stick) Welder.

AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical (earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.

3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

ARC RAYS can burn.

4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.

4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.

FUMES AND GASES can be dangerous.

5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. When

welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.

5.b. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations.

The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products.

5.c. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.

5.d. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.

5.e. Also see item 1.b.

Mar ‘95

Image 3
Contents Synergic 7F and Synergic 7FH Mar ‘95 SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionMar. ‘93 Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Installation Type K678-2 K679-1 K679-2 Wire Speed RangeModel Recommended Processes and Equipment Standard FeaturesWire Feed Features General DescriptionControl Features Y P a D a N D D I S P L a Y Description Mounting the Control Box K678-2 Safety PrecautionsConnecting Wire Feed Unit to Control Box Electric Shock can killAluminum Wire Sizes Procedure to Install Drive Roll and Guide TubesWire Feed Drive Roll and Guide Tube Kits Steel Wire Sizes RollInnershield Guns Gun and Cable Assemblies with Standard L. E. ConnectionsGun Cable Connection Gmaw GunsCylinder may explode if damaged Gun Cable Connections Wire Feeder to GunSynergic 7F Water Connections for Water-Cooled Guns Gmaw Shielding Gas60% Duty Cycle Up to 100 ft Length 30m Electrical InstallationWork Cable CurrentOptional Features Installation K648, K649 or K642 Input Cable Assembly SeeElectrical Installation section for instructions Operating Instructions Power-Down SaveMode Selection OperationDisplay Control Keys Timer/Crater Select key enables Procedure Selector Switch Memory Ammeter Selection4-step with crater fill To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter Feeding Electrode and Brake AdjustmentFeeding Electrode To Mount a 50-60lb 22.7-27.2kg CoilWire Loading of 13-14lb 6kg Innershield Coils Idle Roll Pressure SettingGas Guard Regulator Setting Wire Reel Changing Wire Feed Overload ProtectionMaking a Weld Explanation of Prompting Error Messages Optional Features AccessoriesREADI-REEL Adapters Maintenance MaintenanceTroubleshooting Guide TroubleshootingTrouble shooting information Replace contact tipTions in control cable Replace WeldingIng and gas flow rate is proper IngControl PC board see Procedure for No control of wire feedTers on wire feeder display do not Defective wire feed motor tach orOr there may be a problem with Wire feed motor runs and solenoid Power source is defectiveWiring harness or Control PC Speed does not change when Run-in and weld speeds are setRemote control kit must be used Meters on wire feeder display doNot match those on power Problem with wire feeder harnessTroubleshooting Faulty local dual procedure switch Dure switch Be connectedBetween procedures a and B Display. If not, refer to ProblemFaulty communication between Local dual procedure switchDual procedure switch is used to Switch between procedures aBad Breaker at power source is blownOr tripped Circuit breaker Display or Control PC board isX8 on Control PC board is faulty See Problem 5 or see Section onCedure for replacing PC boards Eprom checksum error Onds. Turn power back on. If EP isSwitch Requirements Procedure for Replacing PC Boards Electric Shock can killControl P.C Board DIAGRAMSF-1Input Connection Diagram DiagramsPrint Wire Feed Unit Dimension Print Synergic 7F & FH Synergic 7F & FH Precaucion Warnung