Lincoln Electric IM559 manual Troubleshooting

Page 36

E-7

TROUBLESHOOTING

E-7

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

16.Wire feeder's display does not change when WFS and/or Volts/Trim knobs of the remote control kit are turned.

a. Loose connection to Remote con- trol receptacle, J22.

b. Faulty Remote PC board.

c. Faulty remote cable.

d. Faulty remote wiring harness.

e. Faulty wire feeder harness or remote cable receptacle.

f. Faulty Control board or Remote PC board.

a. Make sure that remote cable connec- tions are tight.

b. If either the WFS knob, the Volts/Trim knob, or the dual procedure switch of the remote control kit is operating properly then replace the Remote PC board.

c. Remove remote cable from wire feed- er and unplug connector P2 from J2 in remote control kit. Check continuity between pin 1 of J2 and socket B of remote receptacle, between pin 2 of

J2 and socket A of remote receptacle, between pin 3 of J2 and socket D of remote receptacle, and between pin 4 of J2 and socket C of remote recepta- cle. If any of these continuity tests fail then repair or replace remote cable.

d. Remove plug from J1 on Remote PC board and unplug connector P2 from J2 in remote control kit. Check conti- nuity between pin 1 of P2 and pin 2 of P1, between pin 2 of P2 and pin 3 of P1, between pin 3 of P2 and pin 4 of P1, and between pin 4 of P2 and pin 5 of P1. If any of these tests failed, repair or replace remote wiring har- ness.

e. Remove plug from J3 on Control board of wire feeder and remove remote cable from wire feeder. Check continuity between socket A of remote receptacle J22 and pin 2 of plug P3, between socket B of remote recepta- cle and pin 1 of plug P3, between socket C of remote receptacle and pin 3 of plug P3, and between socket D of remote receptacle and pin 4 of plug P3. If any of these tests failed then repair or replace wiring harness. Check continuity between either of the four pins of receptacle J22. If there is continuity between either of the pins then receptacle is faulty.

f.Try replacing Remote PC board. If this does not solve the problem then replace Control board of wire feeder. (See procedure for replacing PC boards.)

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

SYNERGIC 7F & FH

Image 36
Contents Synergic 7F and Synergic 7FH Safety Mar ‘95Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Mar. ‘93Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation Type K678-2 K679-1 K679-2 Wire Speed RangeModel Standard Features Wire Feed FeaturesGeneral Description Recommended Processes and EquipmentControl Features Y P a D a N D D I S P L a Y Description Safety Precautions Connecting Wire Feed Unit to Control BoxElectric Shock can kill Mounting the Control Box K678-2Procedure to Install Drive Roll and Guide Tubes Wire Feed Drive Roll and Guide Tube KitsSteel Wire Sizes Roll Aluminum Wire SizesGun and Cable Assemblies with Standard L. E. Connections Gun Cable ConnectionGmaw Guns Innershield GunsGun Cable Connections Wire Feeder to Gun Synergic 7F Water Connections for Water-Cooled GunsGmaw Shielding Gas Cylinder may explode if damagedElectrical Installation Work CableCurrent 60% Duty Cycle Up to 100 ft Length 30mOptional Features Installation K648, K649 or K642 Input Cable Assembly SeeElectrical Installation section for instructions Power-Down Save Mode SelectionOperation Operating InstructionsDisplay Control Keys Timer/Crater Select key enables Procedure Selector Switch Memory Ammeter Selection4-step with crater fill Feeding Electrode and Brake Adjustment To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm DiameterTo Mount a 50-60lb 22.7-27.2kg Coil Feeding ElectrodeWire Loading of 13-14lb 6kg Innershield Coils Idle Roll Pressure SettingGas Guard Regulator Setting Wire Reel Changing Wire Feed Overload ProtectionMaking a Weld Explanation of Prompting Error Messages Accessories Optional FeaturesREADI-REEL Adapters Maintenance MaintenanceTroubleshooting Troubleshooting GuideTrouble shooting information Replace contact tipTions in control cable Welding Ing and gas flow rate is properIng ReplaceNo control of wire feed Ters on wire feeder display do notDefective wire feed motor tach or Control PC board see Procedure forWire feed motor runs and solenoid Power source is defective Wiring harness or Control PCSpeed does not change when Run-in and weld speeds are set Or there may be a problem withMeters on wire feeder display do Not match those on powerProblem with wire feeder harness Remote control kit must be usedTroubleshooting Dure switch Be connected Between procedures a and BDisplay. If not, refer to Problem Faulty local dual procedure switchLocal dual procedure switch Dual procedure switch is used toSwitch between procedures a Faulty communication betweenBreaker at power source is blown Or trippedCircuit breaker Display or Control PC board is BadSee Problem 5 or see Section on Cedure for replacing PC boards Eprom checksum errorOnds. Turn power back on. If EP is X8 on Control PC board is faultyProcedure for Replacing PC Boards Electric Shock can kill Switch RequirementsDIAGRAMSF-1 Control P.C BoardDiagrams Input Connection DiagramPrint Wire Feed Unit Dimension Print Synergic 7F & FH Synergic 7F & FH Precaucion Warnung