Lincoln 500 manual Remote Control, Output, Auxiliary Power Receptacles, Standby Power Connections

Page 14

A-6

INSTALLATION

A-6

REMOTE CONTROL

OUTPUT

The Vantage is equipped with a 6-pin and a 14-pin connector. The 6-pin connector is for connecting the K857 or K857-1 Remote Control or for TIG welding, the K870 foot Amptrol or the K936-2 hand Amptrol. When in the CC-STICK, DOWNHILL PIPE, or CV- WIRE modes and when a remote control is connected to the 6- pin Connector, the auto-sensing circuit automatically switches the OUTPUT control from control at the welder to remote control.

When in TOUCH START TIG mode and when a Amptrol is connected to the 6-Pin Connector, the OUTPUT dial is used to set the maximum current range of the CURRENT CONTROL of the Amptrol.

The 14-pin connector is used to directly connect a wire feeder control cable. In the CV-WIRE mode, when the control cable is connected to the 14-pin connector, the auto-sensing circuit automatically makes the Output Control inactive and the wire feeder voltage control active

WARNING

NOTE: When a wire feeder with a built in welding voltage control is connected to the 14-pin connector, do not connect anything to the 6-pin connector.

--------------------------------------------------------------------------------------

AUXILIARY POWER RECEPTACLES

The auxiliary power capacity of the Vantage is 12,000 watts of 60 Hz, single phase power or 20,000 watts of 60Hz, three phase power. The auxiliary power capacity rating in watts is equivalent to volt-amperes at unity power factor. The maximum permissible current of the 240 VAC single phase output is 50 A. The 240 VAC output can be split to provide two separate 120 VAC outputs with a maximum permissible current of 50 A per output to two separate 120 VAC branch circuits. The output voltage is within ± 10% at all loads up to rated capacity.

The Vantage has two 20 Amp-120VAC single phase (5-20R) GFCI duplex receptacles and one 50 Amp-120/240 VAC single phase (14-50R) receptacle and one 240VAC three phase (15- 50R) receptacle. The 120/240 VAC receptacle can be split for single phase 120 VAC operation. The auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs. The current rating of any plug used with the system must be at least equal to the current capacity of the associated receptacle.

NOTE: The two 120V GFCI receptacles and the two 120 volt circuits of the 120/240V receptacle are connected to different phases and can not be paralleled.

STANDBY POWER CONNECTIONS

The Vantage is suitable for temporary, standby or emergency power using the engine manufacturer’s recommended maintenance schedule.

The Vantage can be permanently installed as a standby power unit for 240 volt-3 wire, 50 amp service. Connections must be made by a licensed electrician who can determine how the 120/240 VAC power can be adapted to the particular installation and comply with all applicable electrical codes. The following information can be used as a guide by the electrician for most applications. Refer to the connection diagram shown in Figure A.2.

1.Install the double-pole, double-throw switch between the power company meter and the premises disconnect.

Switch rating must be the same or greater than the customer’s premises disconnect and service over current protection.

Vantage 500 CUMMINS

Image 14
Contents Vantage 500 Cummins Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Vii Installation Input Diesel EngineStoring Safety PrecautionsLocation / Ventilation StackingHigh Altitude Operation High Temperature OperationLifting TowingEngine Coolant PRE-OPERATION Engine ServiceBattery Connection OIL Fuel USE Diesel Fuel onlyWelding Terminals Standby Power Connections Remote ControlAuxiliary Power Receptacles OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of LN-7, LN-8 or LN-742 to the Vantage Connection of Lincoln Electric Wire FeedersConnection of AN LN-23P Wire Feeder to the Vantage Connection of LN-15 to the VantageConnection of the LN-25 to the Vantage Connection of Prince XL Spool GUN to the VantageGeneral Description Safety InstructionsOperation Controls and Settings OIL Pressure Gauge Battery Charging LightIdler Switch Engine ProtectionAuxiliary Power Controls Stopping the Engine Engine OperationStarting the Engine Welder Operation BREAK-IN PeriodEngine BREAK-IN Vantage Settings When Using the K930-2 TIG Module For Tungsten ElectrodesAuxiliary Power Operation Operation K767-2 Four Wheeled Steerable Yard Trailer AccessoriesOptional Field Installed Accessories Engine Maintenance MaintenanceRoutine and Periodic Maintenance Cooling System Battery HandlingFuel Filters Welder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideMisadjustments Course of Action Possible Areas RecommendedFunction Problems Possible AreasProblems Possible Areas Diagrams Vangage 500 Cummins Wiring DiagramDIAGRAMSF-2 Connection DiagramCommander / K867 / K775 / LN-7 Connection Diagram DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Engine Welders /LN-8 Connection Diagram ConnectionDiagrams Diagrams Diagrams Diagrams Dimension Print M18962-3Precaucion l Aviso DE