Lincoln 500 manual Auxiliary Power Operation

Page 25

B-8

OPERATION

B-8

CV-WIRE MODE

Connect a wire feeder to the Vantage and set welder controls according to the instructions listed earlier in this section.

The Vantage in the ”CV-WIRE” position, permits it to be used with a broad range of flux cored wire (Innershield and Outershield) electrodes and solid wires for MIG welding (gas metal arc welding). Welding can be finely tuned using the “ARC CONTROL”. Turning the ARC CONTROL clockwise from - 10(soft) to +10(crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance/pinch control. The proper setting depends on the procedure and operator preference. Start with the knob set at 0.

For any electrodes, including the above recommendations, the procedures should be kept within the rating of the machine. For additional electrode information, See www.lincolnelectric.com or the appropriate Lincoln publication.

ARC GOUGING

For optimal performance when arc gouging, set the Vantage “WELD MODE” switch to the “CC - STICK” position, and the “ARC CONTROL” to 10.

Set the “OUTPUT” knob to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table:

*Maximum current setting is limited to the Vantage maximum of 575 Amps.

 

ELECTRODE

CURRENT RANGE

 

DIAMETER

(DC, electrode positive)

 

(1/8”)

30-60 Amps

 

(5/32”)

90-150 Amps

 

(3/16”)

200-250 Amps

 

(1/4”)

300-400 Amps

 

(5/16”)

350-450 Amps

 

(3/8”)

450-575 Amps*

PARALLELING

When paralleling machines in order to combine their outputs, all units must be operated in the CC-STICK mode only at the same output settings. To achieve this, turn the WELD MODE switch to the CC-STICK position. Operation in other modes may produce erratic outputs, and large output imbalances between the units.

AUXILIARY POWER OPERATION

Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings, if no welding current is being drawn.

The auxiliary power of the Vantage consists of two 20 Amp- 120VAC (5-20R) GFCI duplex receptacles and one 50 Amp- 120/240 VAC (14-50R) receptacle. The 120/240VAC receptacle can be split for single phase 120 VAC operation.

The auxiliary power capacity is 12,000 watts of 60 Hz, single phase power. The auxiliary power capacity rating in watts is equivalent to volt-amperes at unity power factor. The maximum permissible current of the 240 VAC output is 50 A. The 240 VAC output can be split to provide two separate 120 VAC outputs with a maximum permissible current of 50 A per output to two separate 120 VAC branch circuits. Output voltage is within ± 10% at all loads up to rated capacity.

NOTE: The two 120V GFCI receptacles and the two 120V circuits of the 120/240V receptacle are connected to different phases and cannot be paralleled.

The auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs.

The current rating of any plug used with the system must be at least equal to the current capacity of the associated receptacle.

SIMULTANEOUS WELDING AND AUXILIARY POWER LOADS

It must be noted that the above auxiliary power ratings are with no welding load. Simultaneous welding and power loads are specified in table B.4. The permissible currents shown assume that current is being drawn from either the 120 VAC or 240 VAC supply (not both at the same time).

Vantage 500 CUMMINS

Image 25 Contents
Vantage 500 Cummins California Proposition 65 Warnings SafetyElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Vii Input Diesel Engine InstallationLocation / Ventilation Safety PrecautionsStoring StackingLifting High Temperature OperationHigh Altitude Operation TowingBattery Connection OIL PRE-OPERATION Engine ServiceEngine Coolant Fuel USE Diesel Fuel onlyWelding Terminals Auxiliary Power Receptacles Remote ControlStandby Power Connections OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of AN LN-23P Wire Feeder to the Vantage Connection of Lincoln Electric Wire FeedersConnection of LN-7, LN-8 or LN-742 to the Vantage Connection of LN-15 to the VantageConnection of Prince XL Spool GUN to the Vantage Connection of the LN-25 to the VantageOperation Safety InstructionsGeneral Description Controls and Settings Idler Switch Battery Charging LightOIL Pressure Gauge Engine ProtectionAuxiliary Power Controls Starting the Engine Engine OperationStopping the Engine Engine BREAK-IN BREAK-IN PeriodWelder Operation For Tungsten Electrodes Vantage Settings When Using the K930-2 TIG ModuleAuxiliary Power Operation Operation Optional Field Installed Accessories AccessoriesK767-2 Four Wheeled Steerable Yard Trailer Routine and Periodic Maintenance MaintenanceEngine Maintenance Fuel Filters Battery HandlingCooling System Welder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingPossible Areas Recommended Misadjustments Course of ActionPossible Areas Function ProblemsProblems Possible Areas Vangage 500 Cummins Wiring Diagram DiagramsConnection Diagram DIAGRAMSF-2Diagram Commander / K867 / K775 / LN-7 Connection DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Connection Engine Welders /LN-8 Connection DiagramDiagrams Diagrams Diagrams Diagrams M18962-3 Dimension PrintPrecaucion l Aviso DE
Related manuals
Manual 51 pages 15.6 Kb