Lincoln Comprehensive Guide to Vantage 500 Specifications, Weight, and Service Manual

Page 9

A-1

 

INSTALLATION

 

A-1

TECHNICAL SPECIFICATIONS - Vantage 500 CUMMINS (K2272-1)

 

 

 

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

Make /Model

Description

Speed (RPM)

Displacement

Starting

Capacities

 

 

 

 

System

 

Cummins

4 cylinder

High Idle 1900

199 cu. in

12VDC battery

Fuel

B3.3

56HP (42 kw)

Low Idle 1425

(3.3L)

& Starter

(25 US gal)

Diesel Engine

@ 1800 RPM

Full Load 1800

 

 

94.6L

 

 

 

Bore x Stroke

 

Oil:

 

 

 

 

 

(2 US gal)

 

 

 

3.74” x 4.53”

 

7.5L

 

 

 

(95mm x 115mm)

 

Coolant:

 

 

 

 

 

(2.6 US gal)

 

 

 

 

 

11.8L

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40°C) - WELDER

Duty Cycle

Welding Output

Volts at Rated Amps

100%

500 Amps (DC multi-purpose)

40 Volts

60%

550 Amps (DC multi-purpose)

36 volts

50%

575 Amps (DC multi-purpose)

35 volts

OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR

Welding Range

30 - 575 Amps CC/CV

20 - 250 Amps TIG

Open Circuit Voltage

60 Max OCV @ 1900 RPM

Auxiliary Power (1)

120/240 VAC

12,000 WATTS, 60 Hz.

PHYSICAL DIMENSIONS

Height (2)

Width

Depth

Weight

42.0 in

31.5 in.

63.1 in.

1605 lbs.

(1066.8 mm)

(800.1mm)

(1603mm)

(728kg)

 

 

 

(Approx)

1.Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.Top of Enclosure. Add 8.8” (223.5mm) for exhaust.

Vantage 500 CUMMINS

Image 9
Contents Vantage 500 Cummins California Proposition 65 Warnings SafetyElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Vii Input Diesel Engine InstallationLocation / Ventilation Safety PrecautionsStoring StackingLifting High Temperature OperationHigh Altitude Operation TowingBattery Connection OIL PRE-OPERATION Engine ServiceEngine Coolant Fuel USE Diesel Fuel onlyWelding Terminals Auxiliary Power Receptacles Remote ControlStandby Power Connections OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of AN LN-23P Wire Feeder to the Vantage Connection of Lincoln Electric Wire FeedersConnection of LN-7, LN-8 or LN-742 to the Vantage Connection of LN-15 to the VantageConnection of Prince XL Spool GUN to the Vantage Connection of the LN-25 to the VantageSafety Instructions OperationGeneral Description Controls and Settings Idler Switch Battery Charging LightOIL Pressure Gauge Engine ProtectionAuxiliary Power Controls Engine Operation Starting the EngineStopping the Engine BREAK-IN Period Engine BREAK-INWelder Operation For Tungsten Electrodes Vantage Settings When Using the K930-2 TIG ModuleAuxiliary Power Operation Operation Accessories Optional Field Installed AccessoriesK767-2 Four Wheeled Steerable Yard Trailer Maintenance Routine and Periodic MaintenanceEngine Maintenance Battery Handling Fuel FiltersCooling System Welder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingPossible Areas Recommended Misadjustments Course of ActionPossible Areas Function ProblemsProblems Possible Areas Vangage 500 Cummins Wiring Diagram DiagramsConnection Diagram DIAGRAMSF-2Diagram Commander / K867 / K775 / LN-7 Connection DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Connection Engine Welders /LN-8 Connection DiagramDiagrams Diagrams Diagrams Diagrams M18962-3 Dimension PrintPrecaucion l Aviso DE