Lincoln 500 manual Commander / K867 / K775 / LN-7 Connection Diagram

Page 37

Vantage 500 CUMMINS

COMMANDER / K867 / K775 / LN-7 CONNECTION DIAGRAM

 

 

WARNING

 

 

 

 

 

Do not operate with panels open.

 

 

Keep guards in place.

 

 

Disconnect NEGATIVE (-) BATTERY LEAD

 

 

Keep away from moving parts.

 

 

before servicing.

 

 

Only qualified personnel should install,use

 

 

Do not touch electrically live parts.

 

 

or service this equipment.

 

 

 

SPARE

}

 

 

 

 

41

 

 

 

 

82

 

 

 

 

 

 

81

 

 

N.D.

LN-7

 

 

 

 

WIRE

 

 

42

 

 

 

 

 

 

 

 

FEEDER

 

 

31

 

 

31

 

 

 

32

 

 

32

 

 

14 PIN

2

 

 

2

 

 

AMPHENOL

4

 

 

 

 

 

 

 

 

4

 

ELECTRODE

TO WORK

21

 

 

21

K291 OR K404

 

K867 UNIVERSAL

 

 

 

 

 

 

 

 

GND

 

 

GND

INPUT CABLE

 

ADAPTER PLUG

 

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

TO WORK

75

 

 

75

 

 

 

76

 

 

76

 

 

ELECTRODE CABLE

77

}

 

77

 

 

TO WIRE FEED UNIT

 

 

CAUTION :

 

 

 

K775 OPTIONAL

 

 

N.E.

 

 

REMOTE CONTROL

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPILICATIONS. SEE OPERATING MANUAL.

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE "SELECTOR" SWITCH TO "WIRE WELDING CV".

PLACE WIRE FEEDER SWITCH TO "WIRE FEEDER WITH CONTROL CABLE POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED,CONTROL IS AUTOMATICALLY SWITCHED TO REMOTE CONTROL.

N.D. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.E. SPLICE LEADS AND INSULATE.

7-2000

CONNECTION

F-3

DIAGRAM:

 

DIAGRAMS

F-3

S23983

Image 37 Contents
Vantage 500 Cummins California Proposition 65 Warnings SafetyElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Vii Input Diesel Engine InstallationLocation / Ventilation Safety PrecautionsStoring StackingLifting High Temperature OperationHigh Altitude Operation TowingBattery Connection OIL PRE-OPERATION Engine ServiceEngine Coolant Fuel USE Diesel Fuel onlyWelding Terminals Auxiliary Power Receptacles Remote ControlStandby Power Connections OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of AN LN-23P Wire Feeder to the Vantage Connection of Lincoln Electric Wire FeedersConnection of LN-7, LN-8 or LN-742 to the Vantage Connection of LN-15 to the VantageConnection of Prince XL Spool GUN to the Vantage Connection of the LN-25 to the VantageOperation Safety InstructionsGeneral Description Controls and Settings Idler Switch Battery Charging LightOIL Pressure Gauge Engine ProtectionAuxiliary Power Controls Starting the Engine Engine OperationStopping the Engine Engine BREAK-IN BREAK-IN PeriodWelder Operation For Tungsten Electrodes Vantage Settings When Using the K930-2 TIG ModuleAuxiliary Power Operation Operation Optional Field Installed Accessories AccessoriesK767-2 Four Wheeled Steerable Yard Trailer Routine and Periodic Maintenance MaintenanceEngine Maintenance Fuel Filters Battery HandlingCooling System Welder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingPossible Areas Recommended Misadjustments Course of ActionPossible Areas Function ProblemsProblems Possible Areas Vangage 500 Cummins Wiring Diagram DiagramsConnection Diagram DIAGRAMSF-2Diagram Commander / K867 / K775 / LN-7 Connection DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Connection Engine Welders /LN-8 Connection DiagramDiagrams Diagrams Diagrams Diagrams M18962-3 Dimension PrintPrecaucion l Aviso DE