Lincoln 500 manual Connection of Lincoln Electric Wire Feeders, Connection of LN-15 to the Vantage

Page 16

A-8

INSTALLATION

A-8

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

WARNING

Shut off welder before making any electrical connections.

-------------------------------------------------------------------------------------

CONNECTION OF LN-7, LN-8 OR LN-742 TO THE VANTAGE

Shut the welder off.

Connect the LN-7, LN-8 OR LN-742 per instructions on the appropriate connection diagram in the DIAGRAMS section.

Set the “WIRE FEEDER VOLTMETER” switch to either “+” or “- ” as required by the electrode being used.

Set the “SELECTOR” switch to the “CV-WIRE” position.

Adjust the “ARC CONTROL” knob to desired Crispness. SOFT for MIG and CRISP for INNERSHIELD.

Set the “WELDING TERMINALS” switch to the “REMOTELY CONTROLLED” position.

Set the “IDLE” switch to the “HIGH” position.

CONNECTION OF LN-15 TO THE VANTAGE

These connections instructions apply to both the LN-15 Across- The-Arc and Control Cable models. The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

Shut the welder off.

For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

Across-The-Arc Model:

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the MODE switch to the "CV-WIRE " position.

Across-The-Arc Model:

Set the "WELD TERMINALS" switch to "WELD TERMINALS ON"

Control Cable Model:

Set the "WELD TERMINALS" switch to "REMOTELY CONTROLLED"

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polarity being used.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "IDLE" switch to the "High" position

CONNECTION OF AN LN-23P WIRE FEEDER TO THE VANTAGE

Shut the welder off.

Connect the LN-23P per instructions on the appropriate connection diagram in the DIAGRAMS section. (NOTE): When connecting an LN-23P to the Vantage, a K350-1 adapter kit must be used.

Set the “WIRE FEEDER VOLTMETER” switch to “-”.

Set the “SELECTOR” switch to “CV-WIRE” position.

Set the “WELDING TERMINALS” switch to “REMOTELY CONTROLLED”.

Set the ARC CONTROL to desired crispness.

Set the “IDLE” switch to the “HIGH” position. If you are using an LN-23P with the K350-1 adapter kit, the electrode is not energized until the gun trigger is closed.

Vantage 500 CUMMINS

Image 16
Contents Vantage 500 Cummins Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Vii Installation Input Diesel EngineSafety Precautions Location / VentilationStoring StackingHigh Temperature Operation LiftingHigh Altitude Operation TowingPRE-OPERATION Engine Service Battery Connection OILEngine Coolant Fuel USE Diesel Fuel onlyWelding Terminals Remote Control Auxiliary Power ReceptaclesStandby Power Connections OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of Lincoln Electric Wire Feeders Connection of AN LN-23P Wire Feeder to the VantageConnection of LN-7, LN-8 or LN-742 to the Vantage Connection of LN-15 to the VantageConnection of the LN-25 to the Vantage Connection of Prince XL Spool GUN to the VantageOperation Safety InstructionsGeneral Description Controls and Settings Battery Charging Light Idler SwitchOIL Pressure Gauge Engine ProtectionAuxiliary Power Controls Starting the Engine Engine OperationStopping the Engine Engine BREAK-IN BREAK-IN PeriodWelder Operation Vantage Settings When Using the K930-2 TIG Module For Tungsten ElectrodesAuxiliary Power Operation Operation Optional Field Installed Accessories AccessoriesK767-2 Four Wheeled Steerable Yard Trailer Routine and Periodic Maintenance MaintenanceEngine Maintenance Fuel Filters Battery HandlingCooling System Welder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideMisadjustments Course of Action Possible Areas RecommendedFunction Problems Possible AreasProblems Possible Areas Diagrams Vangage 500 Cummins Wiring DiagramDIAGRAMSF-2 Connection DiagramCommander / K867 / K775 / LN-7 Connection Diagram DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Engine Welders /LN-8 Connection Diagram ConnectionDiagrams Diagrams Diagrams Diagrams Dimension Print M18962-3Precaucion l Aviso DE