TROUBLESHOOTING
Performing repairs may expose voltage sources, moving parts, or compressed air sources. Personal injury may
occur. Before servicing: Unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
| PROBLEM | CAUSE | CORRECTION | |
| Excessive | Pressure switch does | Move On/Auto/Off lever to | |
| tank pressure | not shut off motor when | the "Off" position, if the air | |
| - safety valve | compressor reaches "cut- | compressor does | |
| pops off. | out" pressure. | not shut off, contact a | |
|
|
| Trained Service Technician. | |
|
| Pressure switch | Contact a Trained Service | |
|
| too high. | Technician. | |
| Air leaks at | Tube fittings are not tight | Tighten fittings where air | |
| fittings. | enough. | can be heard escaping. | |
|
|
| Check fittings with soapy | |
|
|
| water solution. DO NOT | |
|
|
| OVERTIGHTEN. | |
|
|
|
| |
Air leaks at or | Check valve seat damaged. | A defective check valve | ||
inside check |
| results in a constant air leak | ||
valve |
| at the pressure release valve | ||
|
|
| when there is pressure in the | |
|
|
| tank and the compressor | |
|
|
| is shut off. Replace check | |
|
|
| valve. Refer to the "To | |
|
|
| Replace or Clean Check | |
|
|
| Valve" in the "Service and | |
|
|
| Adjustments" section. | |
| Air leaks at | Defective pressure switch | Contact a Trained Service | |
| pressure switch | release valve. | Technician. | |
| release valve. |
|
|
|
| (if equipped) |
|
|
|
|
|
|
|
|
| Air leaks in air | Defective air tank. | Air tank must be replaced. | |
| tank or at air |
| Do not repair the leak. | |
| tank welds. |
| Risk of | |
|
|
| Bursting. | |
|
|
| Do not drill into, weld or | |
|
|
| otherwise modify air tank | |
|
|
| or it will weaken. The tank | |
|
|
| can rupture or explode. | |
|
|
|
|
|
| Air leaks | Leaking seal. | Contact a Trained Service | |
| between head |
| Technician. | |
| and valve plate. |
|
|
|
|
|
|
|
|
A09713 | 24- ENG |