IMPORTANT SAFETY INSTRUCTIONS

Save these instructions

Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.

HAZARD

WARNING: Risk of explosion or fire

What Could Happen

It is normal for electrical contacts within the motor and pressure switch to spark.

If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion.

Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire.

Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.

How To Prevent It

Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors.

If spraying flammable materials, locate compressor at least 20 feet away from spray area. An additional length of hose may be required.

Store flammable materials in a secure location away from compressor.

Never place objects against or on top of compressor. Operate compressor in an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings.

Operate compressor in a clean, dry well ventilated area. Do not operate unit indoors or in any confined area.

Always remain in attendance with the

product when it is operating.

Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use.

A09713

4- ENG

Image 4
Contents AIR Compressor Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ATable of Contents Specification Table Safety Guidelines DefinitionsImportant Safety Instructions Model No 919.195411Hazard Always remain in attendance withAttachments & Accessories What Could HappenElectricity. Like any other electrically Repairs attempted by unqualifiedTo human consumption Your specific applicationResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Equip area of operation with a fire extinguisherAccessories AccessoriesGlossary Duty CycleAssembly Contents of CartonTools Required for Assembly To Install HandleTo Assemble Wheels Assemble Rubber FeetTo Add Oil To Pump Installation To Add OilLocation of the Air Compressor Grounding InstructionsVoltage and Circuit Protection Extension Cords120/240 Dual Voltage Motor On/Auto/Off Switch Regulator Safety Valve OperationKnow Your Air Compressor Quick ConnectHow to Use Your Unit How to Stop Before First Start-upBreak-in Instructions Pressure Release Valve Check ValveHow to Start Before Each Start-UpMaintenance Customer ResponsibilitiesTo Check Safety Valve To Drain TankOil ChangingMotor Pulley/Flywheel Alignment Air Filter Inspection ReplacementAir Compressor Pump Intake and Exhaust Valves Service and Adjustments To Replace or Clean Check ValvePressure Relief Tube Nuts Nu ts Screwdriver Open position nothing is visibleMotor Pressure Switch ReplacementTo Replace Regulator Regulator Arrow To Replace BeltWing Nut Storage Troubleshooting Problem Cause CorrectionPressure reading Problem Cause Correction Problem Cause Correction Garantía ContenidoGarantía Total DE UN AÑO DEL Compresor DE Aire Definiciones DE Normas DE Seguridad Modelo Nº 919.195411Lesiones serias Resultar en lesiones menores o Moderadas Lesiones seriasGuarde Estas Instrucciones Instrucciones Importantes DE SeguridadCómo prevenirlo Advertencia Riesgo de Explosión Qué puede occurrir Cómo prevenirloA09713 36- SP Advertencia Riesgo de Partes Móviles Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Operación Lasegura Qué puede occurrir Glosario AccesoriosCiclo DE Servicio AccesoriosEnsamblado Contenido de la cajaHerramientas necesarias para el ensamble DesempaqueEnsamble de las patas de caucho Ensamble de las ruedasPara agregar aceite a la bomba Instalación Para agregar aceiteELÉCTRICO. Ante Enchufe Perno de Tomacorrientes Conexión aProtección del voltaje y del circuito Cables de extensión eléctricaMotor de doble voltaje 120/240 Operación Conozca su compresor de aireCómo utilizar su unidad Antes del primer arranqueInstrucciones para el asentamiento Válvula de Drenaje LaCómo poner en marcha Coloque el interruptor On/Auto/Off en la posición OffResponsabilidades del cliente MantenimientoRiesgo de Operación Cómo drenar el tanque Cómo verificar la válvula de seguridadAceite Filtro de Aire Inspección y reemplazo Polea y volante AlineaciónServicio Y Ajustes Para reemplazar o limpiar la válvula de retenciónMotor Para volver a arrancarPara reemplazar el regulador Interruptor de presión ReemplazoCambio de la correa Regulador FlechaRiesgo de Operación Insegura Pueden ocurrir serias Tuerca mariposaAlmacenaje Guía DE Diagnóstico DE Problemas Problema Causa CorrecciónNo perfore, suelde ni Alguna porque se debilitaráDesciende cuando Conexiones eléctricas sueltas 57- SP A09713 A09713 58- SP Repair Protection Agreements  Product replacement if your covered product cant be fixedContratos de Protección para Reparaciones MY-HOME Sears Parts and Repair CenterCanada SU-HOGARSM