4 Charging
(Table 4) | CHARGE | RECOVER | Status | Action |
| ||||
|
|
|
|
|
| red | red | Recovery cycle: the | |
|
|
| BP 4000 is being |
|
|
|
| charged for the sec- |
|
|
|
| ond time. |
|
|
|
|
|
|
| >red/orange< | red | Recovery cycle: the | |
|
|
| BP 4000 is being |
|
|
|
| discharged. |
|
|
|
|
|
|
| red | red | Recovery cycle: the | |
|
|
| BP 4000 is being |
|
|
|
| charged once more. |
|
|
|
|
|
|
| green | green | The recovery cycle | Remove the de- |
|
|
| has been success- | vice/BP 4000 from |
|
|
| fully completed and | the charger. |
|
|
| the BP 4000 is fully |
|
|
|
| charged. The |
|
|
|
| charger switches to |
|
|
|
|
|
|
|
|
| mode. |
|
|
|
|
|
|
| green | >red< | The recovery cycle | Press and hold the |
|
|
| failed. Although the | RECOVER key for |
|
|
| BP 4000 is fully | 3 seconds to restart |
|
|
| charged, it has aged | the recovery cycle. If |
|
|
| to the point that its | the problem per- |
|
|
| capacity cannot be | sists, replace the |
|
|
| accurately calcu- | BP 4000. |
|
|
| lated anymore. | Refer to section 7 |
|
|
|
| Troubleshooting. |
|
|
|
|
|
A recovery cycle takes about 8 to 10 hours.
Should the recovery cycle fail on the first run, it will be automatically repeated so the entire cycle will take about 15 to 17 hours. If the second recovery cycle fails, too, the RECOVER LED will start flashing red.
Note: | • | You can start a recovery cycle even if you are not requested to: |
| - | during a normal charging cycle (CHARGE is lit red); |
| - | after the successful completion of a charging or recovery cycle (CHARGE is lit green); |
| - | after a failed recovery cycle (refer to Table 4). |
| 1. | Press and hold the RECOVER key (the RECOVER LED will be flashing green). |
| 2. | Release the RECOVER key, |
| - | when the RECOVER LED changes to red (if you have pressed RECOVER during a nor- |
|
| mal charging cycle) OR |
| - | when CHARGE changes to orange (if you have pressed RECOVER after completion of |
|
| a charging or recovery cycle). |
|
| The recovery cycle will start (refer to Table 4). |
|
|
|
|
|
|
24 | CU 4000 |