Xantrex Technology 806-1840, 806-1544 Precautions for Using Rechargeable Appliances, Regulatory

Page 10

Freedom HF InvChg Owners Guide.book Page viii Tuesday, April 29, 2014 12:10 PM

Precautions for Using Rechargeable Appliances

RISK OF DAMAGE TO RECHARGEABLE APPLIANCES

Most rechargeable battery-operated equipment uses a separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output.

Some chargers for small rechargeable batteries can be damaged if connected to the Freedom HF. Avoid using the following with the Freedom HF:

Small battery-operated appliances like flashlights, razors, and night lights that can be plugged directly into an AC receptacle to recharge.

Some chargers for battery packs used in power hand tools. These affected chargers display a warning label stating that dangerous voltages are present at the battery terminals.

If you are unsure about using your rechargeable appliance with the Freedom HF, contact the equipment manufacturer to find out if the appliance is acceptable for use with an inverter that has a modified sine wave output voltage.

Failure to follow these instructions can damage the unit and/or damage other equipment.

Regulatory

The Freedom HF Inverter/Charger is certified to appropriate US and Canadian standards. For more information see “Regulatory Approvals” on page 45.

The Freedom HF Inverter/Charger is intended to be used for mobile or commercial applications. This inverter/charger is designed for marine applications only when additional drip protection is installed in certain orientations. See the installation guide for information.

It is not intended for other applications as it may not comply with the additional safety code requirements needed for those other applications. See “Limitations On Use” below.

LIMITATIONS ON USE

Do not use in connection with life support systems.

Failure to follow these instructions can result in death or serious injury.

NOTE: The Freedom HF Inverter/Charger is a modified sine wave inverter/ charger. Please ensure your equipment or devices are compatible with modified sine wave prior to usage.

viii

Freedom HF Owner’s Guide

Image 10
Contents Freedom HF Inverter/Chargers Page Date and Revision Exclusion for DocumentationDocument Part Number Product NumbersConventions Used About This GuidePurpose ScopeRelated Information Important Safety Instructions Electrical Shock HazardFire and Burn Hazard Precautions When Working With Batteries Exposure to Chemicals and Gases Hazard Precautions for Using Rechargeable Appliances RegulatoryFCC Information to the User KKK Information to the UserPage Contents Page Introduction Materials ListKey Features Model Low Mid HighFeature Description FeaturesDefault Setting Your Setting Front Panel Freedom HF 1000, 1055, 1500Front Panel Freedom HF 1800 T Front Panel Freedom HF 1055 EMS,1800 EMSSerial number of your unit Display Panel All Models Remote and Power Module Panel Freedom HF 1055 EMS,1800 EMSSide Panel All Models Battery Dip Switch Bulk Float Freedom Inverter/Charger ConfigurationSetting Battery Types on the Main Unit Setting Absorption Switch 1SwitchViewing Inverter/Charger Information Adjusting Feature Settings ScreenTo change the charger’s charging current setting To change the inverter mode setting To adjust the low battery shutdown setting Freedom Inverter/Charger Operation Display Panel OperationFreedom Inverter/Charger Operation Operating in Inverter Mode Operating in Shore Power ModeInverter Mode Setting is on Standby Inverter Mode Setting is OFF Energy Saver 25-hour Automatic Shut OffaStatus LED During Inverter Mode LEDTurning the Audible Alarm on or OFF Checking Battery StatusChecking Output Power Operating Several Loads at OnceTransitioning from Shore Power to Inverter Mode Transitioning from Inverter Mode to Shore PowerOperating Limits Power OutputInput Voltage Operating Voltage Range Comment Condition Freedom HF Only Overload Conditions Over-temperature ConditionsInverter Loads High Surge LoadsTrouble Loads Equipment DamageBattery Charging VoltageBattery Charging Flooded 14.4 13.5 Freedom HF Unit Routine MaintenanceBatteries Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Invert Power Derating vs. Ambient Temperature Troubleshooting Electrical Shock and Energy HazardBuzz in Audio Equipment Common ProblemsTelevision Reception Error Code Condition Mode Action  For error codes  to  Troubleshooting Reference Problem Possible Cause SolutionAC shore power is not available or out Inverter was probably damaged due to the reverse Problem Possible Cause Solution Motor Loads Inverter ApplicationsResistive Loads Long Transfer TimesSpecifications Watt models 1800-watt modelsDC Input AC Input Page Page Schneider Electric Solar Inverters USA Inc
Related manuals
Manual 64 pages 12.33 Kb