Features

Display Panel (All Models)

 

Remote and Power Module Panel

 

 

 

 

(Freedom HF 1055 EMS,1800 EMS)

 

3

1

2

 

 

4

 

HF

1

2

STATUS

 

 

 

 

Utility

Input Voltage (V)

 

 

 

Battery

Select Input Current (A)

 

 

 

Fault

Output Power (kW)

 

 

 

 

 

 

 

Feature Description

1Inverter Power button is the main unit switch that turns the Freedom HF’s inverter function ON or OFF. See page 15 for additional information.

2Three-digit LED display screen shows status information and fault codes. See page 15 for additional information.

3Status LED indicates the mode of operation with a three-color LED. See page 15 for additional information.

4Select button changes status information displayed on the display screen. See page 15 for additional information.

IMPORTANT: See “Display Panel Operation” on page 15 starting on page 15 for detailed information on operating the panel’s buttons.

Feature

Description

 

 

1

Remote jack is used for connecting the Display panel that ships with the

 

Freedom HF 1055 EMS and 1800 EMS. Each shipment comes with a 25-foot

 

communications cable as well.

 

 

2

Power module has one fuse and three contacts for wires that connect to:

 

• an auxiliary 12-volt DC OUT terminal,

 

• an Ignition Control terminal, and

 

• a Disabled terminal.

 

NOTE: The Ignition Control and Disabled terminals are connected

 

by a jumper wire that acts to disable ignition control. Removing the

 

jumper wire will enable ignition control.

 

 

For instructions on how to enable or disable Ignition Control, see the

Installation Guide.

975-0390-01-01

7

Image 21
Contents Freedom HF Inverter/Chargers Page Document Part Number Exclusion for DocumentationDate and Revision Product NumbersPurpose About This GuideConventions Used ScopeRelated Information Electrical Shock Hazard Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Exposure to Chemicals and Gases Hazard Regulatory Precautions for Using Rechargeable AppliancesKKK Information to the User FCC Information to the UserPage Contents Page Materials List IntroductionKey Features Low Mid High ModelDefault Setting Your Setting FeaturesFeature Description Front Panel Freedom HF 1000, 1055, 1500Front Panel Freedom HF 1055 EMS,1800 EMS Front Panel Freedom HF 1800 TSerial number of your unit Freedom HF 1055 EMS,1800 EMS Display Panel All Models Remote and Power Module PanelSide Panel All Models Setting Battery Types on the Main Unit Freedom Inverter/Charger ConfigurationBattery Dip Switch Bulk Float Setting Absorption Switch 1SwitchViewing Inverter/Charger Information Screen Adjusting Feature SettingsTo change the charger’s charging current setting To change the inverter mode setting To adjust the low battery shutdown setting Display Panel Operation Freedom Inverter/Charger OperationFreedom Inverter/Charger Operation Operating in Shore Power Mode Operating in Inverter ModeInverter Mode Setting is on Standby Energy Saver 25-hour Automatic Shut Offa Inverter Mode Setting is OFFLED Status LED During Inverter ModeChecking Output Power Checking Battery StatusTurning the Audible Alarm on or OFF Operating Several Loads at OnceTransitioning from Inverter Mode to Shore Power Transitioning from Shore Power to Inverter ModePower Output Operating LimitsInput Voltage Operating Voltage Range Comment Condition Freedom HF Only Inverter Loads Over-temperature ConditionsOverload Conditions High Surge LoadsEquipment Damage Trouble LoadsVoltage Battery ChargingBattery Charging Flooded 14.4 13.5 Routine Maintenance Freedom HF UnitBatteries Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Invert Power Derating vs. Ambient Temperature Electrical Shock and Energy Hazard TroubleshootingCommon Problems Buzz in Audio EquipmentTelevision Reception  Error Code Condition Mode Action For error codes  to  Problem Possible Cause Solution Troubleshooting ReferenceAC shore power is not available or out Inverter was probably damaged due to the reverse Problem Possible Cause Solution Resistive Loads Inverter ApplicationsMotor Loads Long Transfer TimesWatt models 1800-watt models SpecificationsDC Input AC Input Page Page Schneider Electric Solar Inverters USA Inc