Xantrex Technology 806-1054-01, 806-1840, 806-1055-02, 806-1544 manual DC Input

Page 58

Freedom HF InvChg Owners Guide.book Page 44 Tuesday, April 29, 2014 12:10 PM

Specifications

NOTE: These specifications refer to inverter mode.

 

 

DC Input

1000-watt models

1500 and 1800-watt models

 

 

 

 

Operating voltage range for all models

10.5–15.5 VDC (low limit)

10.5–15.5 VDC (low limit)

 

 

 

 

 

 

 

 

11.8–15.5 VDC (high limit)

11.8–15.5 VDC (high limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating voltage range for Freedom HF 1500

n/a

10.5–15.5 VDC (low limit)

 

 

 

 

and Freedom HF 1800 T

 

 

 

 

11.8–15.5 VDC (mid limit)

 

 

 

 

 

 

 

 

 

 

12.1–15.5 VDC (high limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safe non-operating voltage range

0–16 VDC

0–16 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal voltage for all models

12.5 VDC

12.5 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal current at full load

100 ADC

180 ADC

 

 

 

 

AC Output

1000-watt models

1500 and 1800-watt models

 

 

 

 

 

 

Output voltage

115 VAC

115 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continuous power

1.0kW @ 25 °C

1.8kW @ 25 °C

 

 

 

 

 

 

 

 

 

 

1.5kW @ 25 °C (Freedom HF 1500 only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Surge power

17 AAC

30 AAC

 

 

 

 

 

 

(2kW for 200 ms)

(3.6kW for 300 ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max short-circuit current

55 AAC peak

55 AAC peak

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

60 Hz

60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wave shape

Modified Sine Wave

Modified Sine Wave

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power derating above 40 °C ambient temp

See “Invert Power Derating vs. Ambient Temperature” on page 31.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Peak efficiency

87%

87%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full load efficiency

80%

80%

 

 

 

 

Other

1000-watt models

1500 and 1800-watt models

 

 

 

 

 

 

No load input power (producing output voltage)

10W

10W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off mode current draw

1mA

1mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

 

 

 

 

Freedom HF Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 58
Contents Freedom HF Inverter/Chargers Page Date and Revision Exclusion for DocumentationDocument Part Number Product NumbersConventions Used About This GuidePurpose ScopeRelated Information Important Safety Instructions Electrical Shock HazardFire and Burn Hazard Precautions When Working With Batteries Exposure to Chemicals and Gases Hazard Precautions for Using Rechargeable Appliances RegulatoryFCC Information to the User KKK Information to the UserPage Contents Page Introduction Materials ListKey Features Model Low Mid HighFeature Description FeaturesDefault Setting Your Setting Front Panel Freedom HF 1000, 1055, 1500Front Panel Freedom HF 1800 T Front Panel Freedom HF 1055 EMS,1800 EMSSerial number of your unit Display Panel All Models Remote and Power Module Panel Freedom HF 1055 EMS,1800 EMSSide Panel All Models Battery Dip Switch Bulk Float Freedom Inverter/Charger ConfigurationSetting Battery Types on the Main Unit Setting Absorption Switch 1SwitchViewing Inverter/Charger Information Adjusting Feature Settings ScreenTo change the charger’s charging current setting To change the inverter mode setting To adjust the low battery shutdown setting Freedom Inverter/Charger Operation Display Panel OperationFreedom Inverter/Charger Operation Operating in Inverter Mode Operating in Shore Power ModeInverter Mode Setting is on Standby Inverter Mode Setting is OFF Energy Saver 25-hour Automatic Shut OffaStatus LED During Inverter Mode LEDTurning the Audible Alarm on or OFF Checking Battery StatusChecking Output Power Operating Several Loads at OnceTransitioning from Shore Power to Inverter Mode Transitioning from Inverter Mode to Shore PowerOperating Limits Power OutputInput Voltage Operating Voltage Range Comment Condition Freedom HF Only Overload Conditions Over-temperature ConditionsInverter Loads High Surge LoadsTrouble Loads Equipment DamageBattery Charging VoltageBattery Charging Flooded 14.4 13.5 Freedom HF Unit Routine MaintenanceBatteries Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Invert Power Derating vs. Ambient Temperature Troubleshooting Electrical Shock and Energy HazardBuzz in Audio Equipment Common ProblemsTelevision Reception Error Code Condition Mode Action  For error codes  to  Troubleshooting Reference Problem Possible Cause SolutionAC shore power is not available or out Inverter was probably damaged due to the reverse Problem Possible Cause Solution Motor Loads Inverter ApplicationsResistive Loads Long Transfer TimesSpecifications Watt models 1800-watt modelsDC Input AC Input Page Page Schneider Electric Solar Inverters USA Inc