Introduction

Over-temp Alarm and Shutdown During inverter mode, the Freedom HF automatically alerts you if it is overheating and approaching the over-temperature shutdown limit.

The Freedom HF automatically shuts down when the limit is exceeded.

Low Power Consumption When the Freedom HF is inverting without a load, it draws less than 1 amp of current from the battery (or battery bank).

This feature allows the unit to operate without draining too much stored energy.

Battery-friendly Charging For the inverter to perform effectively, the batteries must be charged correctly. The Freedom HF has a built-in three-stage charging system that extends the life and optimizes the performance of the batteries.

In addition to the numerous features which let you maximize your battery’s life and performance, the Freedom HF—unlike many chargers—also has the ability to recharge a near-zeroavoltage battery and an ignition-switched 20-amp auxiliary 12-volt power sourceb.

a.Near-zero or dead batteries can be recharged. However, some batteries which have been left uncharged for days can become severely damaged thus, recharging is futile. b.Available on the Freedom HF 1055 EMS model and Freedom HF 1800 EMS model. The inverter/charger features a 20-amp fused and switched output voltage supplied from the inverter/charger's positive terminal. When connected to a vehicle's ignition signal, a switched positive voltage is available to power auxiliary circuits that are re- quired to operate only when the vehicle is operational.

Selectable Low Battery Shutdown The low battery shutdown for the inverter can be manually selected by the user by choosing a low, middle, or high setting. The low setting default for low battery shutdown is 10.5 volts except Freedom HF 1500 (PN: 806-1544).

Model

PN

Shutdown Settings (V)

 

 

Low

Mid

High

Freedom HF 1000

806-1020

10.5

n/a

11.8

Freedom HF 1055

806-1054

10.5

n/a

11.8

 

806-1054-01

10.5

n/a

11.8

 

806-1055

10.5

n/a

11.8

Freedom HF 1055 EMS

806-1055-02

10.5

n/a

11.8

Freedom HF 1500

806-1544

12.1

12.1

12.1

Freedom HF 1800

806-1840

10.5

n/a

11.8

Freedom HF 1800 T

806-1840-01

10.5

11.8

12.1

Freedom HF 1800 EMS

806-1840-02

10.5

n/a

11.8

Table 1 Shutdown Settings

Ignition Control The Freedom HF features the ability to inhibit the inverter from operating in the absence of a voltage signal from a vehicle's ignition circuit. This is particularly useful if the inverter is required to operate only when a vehicle's engine is running.

975-0390-01-01

3

Image 17
Contents Freedom HF Inverter/Chargers Page Document Part Number Exclusion for DocumentationDate and Revision Product NumbersPurpose About This GuideConventions Used ScopeRelated Information Electrical Shock Hazard Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Exposure to Chemicals and Gases Hazard Regulatory Precautions for Using Rechargeable AppliancesKKK Information to the User FCC Information to the UserPage Contents Page Materials List IntroductionKey Features Low Mid High ModelDefault Setting Your Setting FeaturesFeature Description Front Panel Freedom HF 1000, 1055, 1500Front Panel Freedom HF 1055 EMS,1800 EMS Front Panel Freedom HF 1800 TSerial number of your unit Freedom HF 1055 EMS,1800 EMS Display Panel All Models Remote and Power Module PanelSide Panel All Models Setting Battery Types on the Main Unit Freedom Inverter/Charger ConfigurationBattery Dip Switch Bulk Float Setting Absorption Switch 1SwitchViewing Inverter/Charger Information Screen Adjusting Feature SettingsTo change the charger’s charging current setting To change the inverter mode setting To adjust the low battery shutdown setting Display Panel Operation Freedom Inverter/Charger OperationFreedom Inverter/Charger Operation Inverter Mode Setting is on Standby Operating in Shore Power ModeOperating in Inverter Mode Energy Saver 25-hour Automatic Shut Offa Inverter Mode Setting is OFFLED Status LED During Inverter ModeChecking Output Power Checking Battery StatusTurning the Audible Alarm on or OFF Operating Several Loads at OnceTransitioning from Inverter Mode to Shore Power Transitioning from Shore Power to Inverter ModeInput Voltage Power OutputOperating Limits Operating Voltage Range Comment Condition Freedom HF Only Inverter Loads Over-temperature ConditionsOverload Conditions High Surge LoadsEquipment Damage Trouble LoadsVoltage Battery ChargingBattery Charging Flooded 14.4 13.5 Batteries Routine MaintenanceFreedom HF Unit Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Invert Power Derating vs. Ambient Temperature Electrical Shock and Energy Hazard TroubleshootingTelevision Reception Common ProblemsBuzz in Audio Equipment  Error Code Condition Mode Action For error codes  to  Problem Possible Cause Solution Troubleshooting ReferenceAC shore power is not available or out Inverter was probably damaged due to the reverse Problem Possible Cause Solution Resistive Loads Inverter ApplicationsMotor Loads Long Transfer TimesWatt models 1800-watt models SpecificationsDC Input AC Input Page Page Schneider Electric Solar Inverters USA Inc