Xantrex Technology 806-1544, 806-1840, 806-1055-02 Specifications, Watt models 1800-watt models

Page 57

Freedom HF InvChg Owners Guide.book Page 43 Tuesday, April 29, 2014 12:10 PM

Specifications

NOTE: Specifications are subject to change without prior notice.

Physical Specifications

1000-watt models

1500 and 1800-watt models

L × W × H

15.5” (393mm) × 9.5” (241mm)× 4.2” (106mm)

18” (457mm) × 9.5” (241mm)× 4.2” (106mm)

Net Weight

10 lbs (4.5 kg)

12.8 lbs (5.8 kg)

 

 

NOTE: Excludes any external AC or DC wiring

 

 

harnesses included on some models.

Environmental Specifications

1000-watt models

 

1500 and 1800-watt models

Ambient Temperature:

 

0–40

ºC

Operating Temperature Range

-20–60 ºC, with output derated above 25 °C

Storage Temperature Range

 

-40–70 ºC

 

 

Humidity: Operation/Storage

5–95% RH, non-condensing

 

 

 

 

System Specifications

1000-watt models

 

1500 and 1800-watt models

Transfer relay rating

 

30A,

2.0hp

 

 

 

Transfer time

 

<30ms (milliseconds)

 

 

Transfer on bad voltage

90–100V for low AC and 130–140 for high AC

 

 

Cooling

Fan, activated by any of the following:

 

 

•High internal temperature

 

 

•High AC output power

 

 

 

 

43

Freedom HF Owner’s Guide

Image 57
Contents Freedom HF Inverter/Chargers Page Document Part Number Exclusion for DocumentationDate and Revision Product NumbersPurpose About This GuideConventions Used ScopeRelated Information Electrical Shock Hazard Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Exposure to Chemicals and Gases Hazard Regulatory Precautions for Using Rechargeable AppliancesKKK Information to the User FCC Information to the UserPage Contents Page Materials List IntroductionKey Features Low Mid High ModelDefault Setting Your Setting FeaturesFeature Description Front Panel Freedom HF 1000, 1055, 1500Front Panel Freedom HF 1055 EMS,1800 EMS Front Panel Freedom HF 1800 TSerial number of your unit Freedom HF 1055 EMS,1800 EMS Display Panel All Models Remote and Power Module PanelSide Panel All Models Setting Battery Types on the Main Unit Freedom Inverter/Charger ConfigurationBattery Dip Switch Bulk Float Setting Absorption Switch 1SwitchViewing Inverter/Charger Information Screen Adjusting Feature SettingsTo change the charger’s charging current setting To change the inverter mode setting To adjust the low battery shutdown setting Display Panel Operation Freedom Inverter/Charger OperationFreedom Inverter/Charger Operation Operating in Shore Power Mode Operating in Inverter ModeInverter Mode Setting is on Standby Energy Saver 25-hour Automatic Shut Offa Inverter Mode Setting is OFFLED Status LED During Inverter ModeChecking Output Power Checking Battery StatusTurning the Audible Alarm on or OFF Operating Several Loads at OnceTransitioning from Inverter Mode to Shore Power Transitioning from Shore Power to Inverter ModePower Output Operating LimitsInput Voltage Operating Voltage Range Comment Condition Freedom HF Only Inverter Loads Over-temperature ConditionsOverload Conditions High Surge LoadsEquipment Damage Trouble LoadsVoltage Battery ChargingBattery Charging Flooded 14.4 13.5 Routine Maintenance Freedom HF UnitBatteries Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Invert Power Derating vs. Ambient Temperature Electrical Shock and Energy Hazard TroubleshootingCommon Problems Buzz in Audio EquipmentTelevision Reception  Error Code Condition Mode Action For error codes  to  Problem Possible Cause Solution Troubleshooting ReferenceAC shore power is not available or out Inverter was probably damaged due to the reverse Problem Possible Cause Solution Resistive Loads Inverter ApplicationsMotor Loads Long Transfer TimesWatt models 1800-watt models SpecificationsDC Input AC Input Page Page Schneider Electric Solar Inverters USA Inc