Powerware 685 installation manual Series 1085 Battery Cabinet Wiring Detail

Page 25

BATTERY

BREAKER

FIXED RIGHT BATTERY

POWER CONNECTOR

(BLACK)

STRING

CONNECTORS

(RED)

CONNECTION FOR

REMOTE

MONITORING

CUSTOMER CONNECTION CABINET GROUNDING (REMOTE INSTALLATION)

CABINET TO CABINET

TERMINAL (---)

NOTE: COMPRESSION LUGS

SHOWN ARE USED FOR

REMOTE INSTALLATION

ONLY

CABINET TO CABINET

TERMINAL (+)

GROUNDING STUD

LOCATION (2X)

CABLE ACCESS LOCATION

LEVELING FEET

Figure 12. Series 1085 Battery Cabinet Wiring Detail

 

 

 

Powerware 9350 Series 685 and 1085 Auxiliary Battery Cabinets

19

Installation Manual 164201408 Rev. P00 053002

 

 

Image 25
Contents Series 685 Auxiliary Battery Cabinets Important Safety Instructions General Notes About Installing Battery Cabinets Conventions Used in This Manual Table of Contents Typical Battery Cabinets Introduction Typical Battery CabinetsUPS Identification of Your Battery SystemBattery Cabinets Getting Help For More InformationPreparing for Wiring the Battery Cabinet Unpacking Your Battery CabinetPreparing Your Site Environmental ConsiderationsOuter Packaging PLY---FOAM Cushions Inspecting and Unpacking Each CabinetUnloading the Battery Cabinet from the Pallet Removing Front and Rear Supports Creating an Installation Plan Page Powerware 9350 UPS with Integral Battery Cabinets Connecting to Powerware 9350 30Installation Manual 164201408 Rev. P00 See for Series TOP View Front View Attaching UPS Base to Series 685 Base Installation Manual 164201408 Rev. P00 Series 685 Battery Cabinet Wiring Detail Series 685 Cabinet Series 1085 Battery Cabinet Wiring Detail UPS with Separately Located Battery Cabinets Powerware 9350 UPS with Separately Located Battery CabinetsSeparate Installation of Series 685 Battery Cabinets Connecting Two Series 685 Bases Separate Installation of Series 1085 Battery Cabinets Connecting Two Series 1085 Bases To Electrically Connect Separate Battery Cabinets to the UPS Installation Manual 164201408 Rev. P00 Installation Checklist for Powerware 9350 30 through Completing the Installation ChecklistThis Page Intentionally Left Blank Battery Connections for a Powerware Connecting to Powerware 9350 ---80Powerware 9350---80 or 160 with Separate Battery Cabinets Completing the Installation Checklist Installation Checklist for Powerware Remote Battery Disconnect Enclosure Installing a Remote Battery Disconnect31.1 N-M 255---275 lb-in Table A. Remote Battery Disconnect Power Terminations Table C. Remote Battery Disconnect Circuit Breaker Ratings Appendix a --- Customer Information Series 685 / 1085 ConfigurationsIntegral Tool Size Torque Battery Cabinet UPS Cabinet 375 200 Type Series 685 Battery Cabinet TOP View Series 1085 Battery Cabinet Series 1085 Battery Cabinet plan TB1 164201408--4 This Page Intentionally Left Blank