Additional Service
Disassembly or service of the air compressor beyond what is covered in this manual is not recommended. If additional service is required, contact your near- est Authorized Warranty Service Center.
STORAGE
Before you store the air compressor, make sure you do the following:
1.Review the Maintenance section on the preceding pages and perform sched- uled maintenance as necessary.
2.Set the Auto/Off lever to "Off".
3.Close the globe valve.
4.Remove the air tool or accessory.
5.Open the globe valve and allow the air to slowly bleed from the air tank until tank pressure is approximately 20 psi.
6.Drain water from air tank by opening drain valve on bottom of tank.
Water will condense in the air tank. If not drained, water will cor- rode and weaken the air tank causing a risk of air tank rupture.
7.After the water has been drained, close the drain or drain valve.
NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.
8.Protect the air hose from damage (such as being stepped on or run over).
REPLACEMENT PARTS SERVICE
Use only identical replacement parts. For a parts list or to order parts, visit our service website at www.deltaportercableservicenet.com. You can also order parts from your nearest
SERVICE AND REPAIRS
All quality tools will eventually require servicing and/or replacement of parts. For infor- mation about
You can also write to us for information at
ACCESSORIES
Since accessories, other than those offered by
A complete line of accessories is available from your
19 - ENG | N020206 |